1
INSTRUCTION MANUAL
Balances
Ohaus Corporation
Ohaus Corporation29 Hanover RoadFlorham Park, NJ07932-0900
Page 1: ...1 INSTRUCTION MANUAL Balances Ohaus Corporation Ohaus Corporation Ohaus Corporation Ohaus Corporation Ohaus Corporation 29 Hanover Road Florham Park NJ 07932 0900...
Page 2: ...usata una radio in prossimit della bilancia Eliminata la fonte dell interferenza il prodotto pu essere nuovamente utilizzato per le funzioni cui preposto EU 73 23 Low Voltage EU 73 23 Niederspannung...
Page 3: ...sti nygarantfadecalidad ISOserie9000 Conocasi ndelasinspeccionesderepetibilidadporpartedelaBVQI secompruebaperi dicamentesielsistemade calidadsemanipuladeformacorrecta CertificatoISO9001perlaOhausCorp...
Page 4: ...3 OPERATINGYOUR BALANCE 11 3 1 The Menu Basic Settings of the Instrument 11 3 2 Turning On the Balance 12 3 3 Calibration 12 3 3 1 Internal Calibration InCalTM 14 3 3 2 Calibration message 15 3 3 3 Ca...
Page 5: ...34 4 8 Units 35 4 9 Global 35 4 10 Custom Unit 37 4 11 Auto Shut Off 39 4 12 Menu Lock Out Protection 40 4 13 Weigh Below 40 5 CARE AND MAINTENANCE 41 5 1 Troubleshooting 41 5 2 RS232 Interface 42 5...
Page 6: ...me readout GLP data GLP set print RS232 mode units global custom and auto shut off 5 O T button When pressed performs tare or rezero function 6 button When pressed travels up through menus 7 button Wh...
Page 7: ...cters are used to present features and functions Units Is displayed when the Units button is pressed Allows the user to know what area of the balance menu is being addressed B G NET Not used 10 Setup...
Page 8: ...e balance is straightforward and easy Setup is simple with 4 cursor keys straightforward menus and prompts that easily guide you through the process NavigatorTM is designed with contours for easy clea...
Page 9: ...ield On 810g to 8100g balances a wind shield is provided to reduce the possibility of air currents from disturbing the pan When the wind shield is in place air currents are deflected up over the pan P...
Page 10: ...onal printer or computer is going to be used with the balance connect an Ohaus RS232 Interface Cable to the connector at the rear of the balance and the external device Refer to paragraph 5 7 Accessor...
Page 11: ...by an on or off selection made in the Setup menu under the Mode menu Units Button The Units button when pressed allows you to select or change units Setup Button The Setup button when pressed allows...
Page 12: ...efer to paragraph 3 3 and calibrate the balance before proceeding 3 3 Calibration Navigator balances offer a choice of five calibration methods Internal Calibration InCALTM Span Calibration User Calib...
Page 13: ...orized personnel from changing calibration If calibration has been locked out you can only access Cal Test To lock out calibration menu after calibration refer to the section titled Menu Lock Out Prot...
Page 14: ...s displayed Press Enter button CAL TYP InCAL is displayed Press Enter button INCAL is displayed Procedure NOTE If a weight is left on the pan the balance will display CLR PAN remove the weight from th...
Page 15: ...Press or button and select either ON or OFF When OFF is selected the CAL NOW message will not appear in the display Press Enter button SAVED is momentarily displayed then the display indicates CAL AD...
Page 16: ...isplayed Press button until CAL ADJ is displayed Press Enter button CAL ADJ 0 should be dis played 0 is factory setting NOTE Balance will retain last CAL ADJ setting Press or button until desired numb...
Page 17: ...ion CAL TYP SPAN is displayed Press Enter button BUSY is displayed NOTE If a weight is left on the pan the balance will display CLR PAN remove the weight from the pan The balance automatically resumes...
Page 18: ...button the display indicates the last calibration mass value which was entered with the first digit flashing Sample illustrates 200g Press to change value of digit and button to advance to next digit...
Page 19: ...ace specified calibration mass on pan Press Enter button BUSY is displayed After a few seconds display changes to PUT WT 200 g The displayed weight is the full capacity of the balance Place specified...
Page 20: ...played NOTE If a weight is left on the pan the balance will display CLR PAN remove the weight from the pan The balance automatically resumes calibration Display changes to PUT WT 200 g The displayed w...
Page 21: ...performing Span calibration with all GLP options turned on a printout is automatically made after the calibration is completed Linearity Calibration Printout When performing a Linearity calibration wi...
Page 22: ...it Press Enter button balance is now ready for weigh ing Place the object s or material to be weighed on the pan Example illustrates a 200 gram weight on a high capacity model Wait for the stability i...
Page 23: ...ily blanks while the balance is taring out Put the reference load on the pan Press or button and select reference weight percentage Percent Range 5 to 100 Hold button down for fast change Press Enter...
Page 24: ...reference weight of an individual part for five seconds and then displays the total number of parts on the pan Place parts to be counted on the pan Balance dis plays number of parts To view the total...
Page 25: ...ut pressing any buttons When the balance displays READY simply place the subject on the pan 3 7 Animal Weighing Animal Weighing is enabled only when Animal is turned ON in the Mode menu under Setup Re...
Page 26: ...pressing to change the digit and to go the next digit The sample display indi cates 0199 00g Press Enter button to continue Place item to be checked on the balance pan ACCEPT is displayed when the it...
Page 27: ...printer or computer will occur each time the Print button is pressed unless the autoprint feature is turned on in which case printing can occur in a continuous fash ion at specified intervals or each...
Page 28: ...tered press Enter button SAVED displays momentarily and ADJUST appears Press Enter button 0 appears Adjustments up to 60 seconds per day can be made to the balance internal clock Using arrow buttons e...
Page 29: ...balance maintains the zero display until the threshold is exceeded Factory default setting is shown in bold type OFF Turns Auto Zero OFF 5 d Sets threshold to 5 divisions 1 d Sets threshold to 1 divis...
Page 30: ...d then EXIT Press Enter button balance returns to weigh mode Press the Setup button CAL is displayed Press button until GLPSET is displayed Press Enter button to continue Press or button until either...
Page 31: ...ss Enter button to continue Press or button and select either menu settings of ON or OFF or settings shown below Press Enter button to save setting Press or button to select next item or EXIT Press En...
Page 32: ...hen set OFF entries may be changed OFF is the default setting Refer to paragraph 4 12 for Menu Lock Out Protection 12 01 98 12 01 37 AM 129 50 g 12 01 98 12 01 52 AM Bal Id 129 80 g 12 01 98 12 02 17...
Page 33: ...when the hardware Lock Switch is set OFF disabled A menu is locked when the menu lock is set ON and the Lock Switch is ON Lock when selected and turned on locks all of the entries made under the RS23...
Page 34: ...lance then view other loads as a percentage of the reference Selection is made using the Mode button The default setting is OFF Count Count is used for counting quantities of parts Selection is made u...
Page 35: ...ftware revision of the balance is displayed Global Reset when set ON will reset all menus to factory default settings only if the Lock Switch is set OFF This is a convienent method of restoring factor...
Page 36: ...7 Stable Print On NU On GLP Cont Off GLP on Tare Off Print Ref On RS232 2400 N 7 2 SAMPLE PRINTOUTS The partial sample shown indicates the status in the menus Global Reset RESETTING ALL MENUS Global R...
Page 37: ...23 x 001 123 x 10 3 EXPONENTS E 3 Moves decimal point 3 places to the left E 2 Moves decimal point 2 places to the left E 1 Moves decimal point 1 place to the left E0 Leaves decimal point in normal po...
Page 38: ...ress Enter button to continue LSD is displayed There are 6 LSD least significant digit settings you can choose from see table below Press Enter button LSD 1 is displayed Press or button and select LSD...
Page 39: ...et a specific time proceed as follows Procedure Press the Setup button CAL is displayed Press button until AUTOFF is displayed Press Enter button TIMER is displayed Press Enter button if a 0 appears t...
Page 40: ...od to move the switch setting A paper clip opened up will work Remember this switch when set on will lock all menus parameters which have the Lock set ON Select the desired position on the Lock Switch...
Page 41: ...splay weight in desired unit Unable to store menu settings changes RS232 interface not working Random segments displayed or display locks up Unable to change settings Unstable readings Error message d...
Page 42: ...5 V dc Interfaces not utilizing the CTS handshake may tie pin 5 to pin 6 to defeat it IMPORTANT An Ohaus RS232 cable is required to operate with this balance A standard RS232 cable will not work See A...
Page 43: ...n numeric only data is selected for output in the RS232 menu the Mode field is not output Same as command Displayed weight sent right justified w lead zero blanking Seven characters include decimal po...
Page 44: ...d must be at least 50 of full span value enter full numerical value with no decimal point LE Show Last Error Code Response Err Error Number SN Show Serial Number xS Print Stable Only Where x 0 Off and...
Page 45: ...serviced 8 3 Rated capacity exceeded Remove excessive weight from pan 8 4 Underload condition on balance Check that the proper pan is installed CheckSum Errors 9 1 Bad factory checksum If error persi...
Page 46: ...5cm 300210 01 Glass draft shield for 32g Navigator 300233 01 Draft shield cover for 32g Navigator 300234 01 Scoop for 32g Navigator 5077 00 30g Calibration mass for 32g Navigator 53034 00 5 7 Accessor...
Page 47: ...10 N08110 N08110 N08110 N0B110 N0D110 N0B110 N0D110 N0B110 N0D110 N0B110 N0D110 N0B110 N0D110 N0H110 N0H110 N0H110 N0H110 N0H110 Item No w Incal Item No w Incal Item No w Incal Item No w Incal Item No...
Page 48: ...ged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In l...
Page 49: ...49 OhausCorporation 29HanoverRoad Florham Park NJ 07932 USA Tel 973 377 9000 Fax 973 593 0359 With offices worldwide Ohaus Corporation 1999 all rights reserved P N 300280 020...