88
OETIKER EPC 01
aPPenDIX
Issue 11.22
08905306
13 3 2 Profinet
The corresponding GsDMl file can be downloaded from the oeTIKeR homepage (visit: www.oetiker.com).
When configuring the hardware, 128 input bytes and 128 output bytes must be defined:
The structure for the applicable mapping is the same for all industrial communication types and is described in
.
The IP address and the device name can be assigned via the usual programs (hardware configuration siemens
step7, Pronenta, etc.).
13 3 3 EtherNet / IP
The corresponding eDs file can be downloaded from the oeTIKeR homepage (visit: www.oetiker.com).
When configuring the hardware, 128 input bytes and 32 output bytes must be defined:
Parameter
Assembly Instance
Size [bytes]
Input
101
128
output
100
32
The structure for the applicable mapping is the same for all industrial communication types and is described in
.
Use a web browser in order to assign the IP address. When delivered, the IP address 192.168.10.215 is assigned
to the industrial communication interface.