85
OETIKER EPC 01
aPPenDIX
Issue 11.22
08905306
13 2 5 Interface X3, RS232
Parameter
Value / Description
Designation
X3
Type
Rs232 (9-pin D-sub)
Usage
Connection and communication with PC software:
•
Read and write local data sets
Connection and communication with Cal 01:
•
sending the measured mean value to the Control Unit
•
authorize pincer test
Two different protocols are used for communication. In the PC software, the corresponding
device is selected for communication.
13 2 6 USB Interface
Parameter
Value / Description
Designation
Usb
Type
Usb socket
Usage
Interface for short-term communication with the PC (e.g. service):
•
Update the firmware of the Control Unit
Cable specification
•
Cable length ≤ 3 m
•
Install a ferrite ring at the end of the cable (near the Usb socket)
13 2 7 Ethernet interface
Parameter
Value / Description
Designation
ethernet
Type
lan socket (RJ45)
Usage
Interface for permanent communication with the PC:
•
send configuration data to the ePC 01
Cable specification
lan cable, at least category 5