TRoUblesHooTInG anD eRRoR MessaGes
Issue 11.22
08905306
11 4 Troubleshooting measures without error messages
The following table describes selected errors that are not indicated by an error message in the display of the Con-
trol Unit.
Description of fault
Cause of the error
Troubleshooting measures
When updating the firmware,
the following message is
displayed in the PC software:
«Connect to Control Unit»
•
Driver not installed or obsolete
►
Install the correct driver on the PC
(
no connection establishment to
the Control Unit via ethernet
•
Control Unit and PC are not con-
nected in the same network
•
Wrong connection on the control-
ler unit is used
►
Check the IP configuration in the
PC software and make sure that
the IP address and subnet mask
are correct.
►
on the Control Unit, use the
ethernet port for the connection
(bottom side of the device).
no values can be sent from
Cal 01 to ePC 01 during the
pincer test
•
Incorrect setting of active X3
interface in the PC software
•
Wrong cable used
►
In the PC software, navigate to
the «Control Unit settings» screen
and set the «active X3 interface»
to «Cal 01».
►
Use the correct cable.
aPn / sequence cannot be
selected
•
no aPn / sequence created
•
aPn / sequence does not match
connected pincer type
Perform actions in the following se-
quence until the error is eliminated:
►
Resend the data set.
►
ensure the correct type of pincer
and reconnect the pincer.
The changes in the data set
were not applied after sending
error not acknowledged
Perform actions in the following se-
quence until the error is eliminated:
►
acknowledge error.
►
Resend the data set.
aPn which was used for a
sequence cannot be deleted.
It cannot be deleted even if
the sequence has since been
removed from the data set.
Data set not saved before deleting
the aPn
►
save the data set and then re-
move aPn from the sequence.
The holding function aborts be-
fore the holding force or holding
point is reached.
Holding force set too low so that the
controller does not function properly
in this range
►
Increase the holding force.
Contact detection shows un-
usual values
Contact force set too low, so that the
controller does not function properly
in this range
►
Increase the contact force.
Closing is canceled when de-
tecting and/or contact detec-
tion are activated
forces set incorrectly, so that a logi-
cal error causes the ePC 01 to abort
the closure process
►
observe the following rule when
setting the forces:
Holding force/detection force
< Contact force < Closing force