OETIKER EPC 01
TRoUblesHooTInG anD eRRoR MessaGes
Issue 11.22
08905306
11 3 Troubleshooting measures for error messages
11 3 1 Remedying errors of the «System» error type
Error message
Cause of the error
Troubleshooting measures
SE1001
Incorrect or no data from pressure /
temperature sensor, valve sensor or
travel measuring system
►
switch the Control Unit off. after approx. 20 s,
switch the Control Unit on and check that the data
are displayed correctly.
►
If the error message appears again, change the
pincer (if possible).
►
If the error message can be acknowledged, send
in the defective pincer. If the error message cannot
be acknowledged, send in the defective Control
Unit.
SE1002
Inlet pressure in the Control Unit fell
below the threshold value during
crimping
►
ensure the following:
•
The pressure accumulator is installed.
•
The supply pressure is sufficient.
•
The flow rate at the pre-filter is sufficient.
►
Reduce the closure force if necessary.
SE1003
•
Max. permissible friction force
of the pincer was exceeded
•
friction in the pincer head is
too great
•
Pincer head is obstructed
►
Check that the plunger of the pincer head lies be-
tween the rollers. If necessary, realign the plunger.
►
If the error cannot be resolved return the defective
pincer.
SE1004
firmware is not compatible with the
new pincer
►
Update the firmware of the Control Unit
(Customer admin).
►
send in the pincer and have the firmware updated.
SE1005
no data received from the propor-
tional valve
►
send in the Control Unit and have it serviced.
SW2001
Preset number of closures until
maintenance of the Control Unit
has been reached
►
send in the Control Unit and have it serviced.
SW2002
The log memory on the Control Unit
is 90% full.
(this message appears only in the
log)
►
Read log memory and then delete it. If the log
memory is not deleted, the oldest entries are over-
written automatically.
SW2003
Temperature too low (≤ 10°C)
►
Use the device within the working temperature
range (
►
To avoid damage to the pincer and Control Unit,
ensure that there is no water in the compressed
air system.
SW2004
Preset number of closures until
maintenance of the pincer is trig-
gered
►
send in the pincer and have it serviced.
SI3001
When updating the firmware, the
fRaM of the Control Unit was
deleted
►
Update the firmware (Customer admin).