6 3 Proceed with the closure functions
NOTICE
In order to ensure consistent and reproducible quality of the working process, the pincer test
must be performed before the start of the shift, but in any case at least once a day. a pincer test
is also required if components of the pincer have been changed.
after the mandatory pincer test, oeTIKeR recommends the closure force should be checked
using the Cal 01.
9
ePC 01 switched on.
1. ensure that the correct closure data for the application is on the Control Unit.
2. select the intended aPn for the application.
3. Proceed with the pincer test (
).
4. Insert one ear of each oeTIKeR clamp (1) into the clamping area on the pincer head (2).
for low-profile clamps:
5. Position the pincer jaws on the closure hooks of the
low-profile clamp.
6. Trigger closure:
–
Press and hold the safety lever (4).
–
Press the sTaRT key (3).
The crimping process is triggered and the ear (5) in the clamp is closed.
•
The pincer jaws crimp the ear, using the preset force.
•
When using clamps, the preset value is used so that the
clamp is hooked in.
after the preset parameter values have been reached, the pincer jaws on the pincer head are opened.
7. after crimping, release the safety lever per closure, but can be held up to a maximum of 20 closures.