Description
16
GA10218_002_A7 - 9/2015 - © Oerlikon Leybold Vacuum
Electrical data
Other data
Ambient conditions
Power supply
Cat.-No.250000V01
Cat.-No.251000V01
Cat.-No.251100V01
230 V, +/- 5%, 50/60 Hz
115 V, +/- 5%, 60 Hz
100 V, +/- 5%, 50/60 Hz
Power consumption
420 VA
Type of protection
IP40
Valves
solenoid
Dimensions (L × W × H) in mm
495 x 456 x 314
Weight in kg
40.0
Noise level dB (A)
< 54
max. Audio alarm dB (A)
90
Contamination level (to IEC 60664-1)
2
Overvoltage category (to IEC 60664-1)
II
For use within buildings
Permissible ambient temperature (during operation) +10 °C … +40 °C
Permissible storage temperature
-10 °C … +60 °C
Maximum relative humidity
80% (up to 31°C) lin-
ear decreasing to
50% at 40°C
Max. permissible height above sea level
(during operation)
2000 m
Electrical data
Other data
Ambient conditions