BYC07HE Programming Touch Screen Heating Thermostat
User Manual
[General]
This Thermostat is applicable to water system and electric-heated system with high power. According to the preset temperature value,
thermostat will automatically start or stop the controlled object (Such as valve, heating floor, heating wall, electric heater etc). It will enable you to
live in an energy-saving and comfortable living environment.
• With the latest single-chip computer control technology, the heating equipment is anti-jamming and extremely stable.
• Multiple time modes: 5+2/6+1/7days, the heating equipment supports different temperature setting accordingly with 6 time-modes daily.
• Users are free to choose manual mode or full automatic mode for different purposes.
• Using flame resistance material, the heating equipment is safe and reliable.
• The clock would continue to run even if power was cut off and it will not affect the period setting value.
• Keypad locking function is designed to prevent the children from misusing.
[Technical parameters]
• Power Supply: 85-250VAC 50/60 Hz
•The maximum switch power: 2A/16A
• Internal sensor measurement range: 0 - 40
℃
.
Setting range: 5 - 35
℃
(factory settings: 25
℃
)
• External sensor measurement range: 0 - 95
℃
.
Setting range: 0 - 90
℃
(factory settings: 50
℃
)
• Monitor type: Touch screen with LCD
•Display area: 60 x 45 mm
• Setting Unit: 0.5
℃
/step
• Display resolution: 0.1
℃
•Inside sensor: NTC B=3380 10k @25degrees Celsius
• Extra sensor: NTC B=3380 10k @25 degrees Celsius, length=3 meters
• When the working temperature of thermostat is below 0 degrees or thermostat’s detected temperature is below 0 degrees, screen would
display as 0 degrees.
[Temperature control mode]
According to the sensor setting of thermostat, there are three different control modes, enter the advance function to set.
Internal control (IN): Only enable built-in sensor temperature measurement, the temperature control is based on the built-in temperature sensor. It
is suitable for the detection of air temperature or the room temperature.
External control (OUT): Only enable external sensor to temperature measurement, the temperature control is based on the external sensor. It is
suitable for the detection of the heating body temperature.
Dual temperature control (ALL): Temperature control is based on the built-in temperature sensor and an external temperature sensor
(over-temperature protection). It is suitable for the detection of room temperature and heating body whether over-temperature monitoring. If the
external sensor is over temperature, thermostat will shuts down the heater.
[Display three kinds of temperature]
The thermostat’s main screen shows air temperature or room temperature when it is under
IN
or
ALL
temperature controlling mode, The AIR icon
would be lit, the vice-monitor would alternatively display temperature value and current time every 5 seconds.
When the thermostat is under
OUT
temperature controlling mode, the
FLOOR
icon would be lit,, the main screen would display floor
temperature or the tested temperature of the external sensor location.
When the temperature is under
ALL
temperature controlling mode, press
and
the main screen would display floor temperature or the
tested temperature of the external sensor location. And the
FLOOR
icon would be lit. The main screen will automatically display air temperature
5 seconds later. Then the
AIR
icon would be lit.
Operation Guide
[On and off]
Press
keys you can turn on or turn off the thermostat.
The display would be as the left picture when turning off:
[System time]
You need to adjust system time when it comes to use at the first time.How to set the system time: Keep pressing
for 5 seconds
,
it will enter
into the time setting. The current revisable object will flash and display. Press
and choose time you want to revise (week / hour / minute),
Week
Stage
Value for Week or Stage
Measured values
Settings values
System clock
Seconds
LOCK
Auto model
Heating
Floor temperture
Air temperture
Power On/Off
Clock
Menu
Up