73
If the CN1 connector pins where the zero clamp function is allocated
are ON, the voltage command below the level set at SEt-17 will be
ignored. When the value of the speed command surpasses this level
again, the motor will accelerate to the value of the command.
In Speed Function
/V-COM signal displays that the error between the motor revolution
speed and the speed command value is kept within a certain range.
This signal can be used as an interlock signal at the controller just as
the position completion detection /P-COM signal at the position
control mode can.
Please set the decision range for in speed match at
SEt-18. The setting range is 0 to 1000 RPM and the
default value is 10.
If the in speed is 100 and the speed command is 2000 RPM, /V-COM
signal is ON and displayed when the actual revolution speed is 1900
RPM or higher and 2100 RPM
or lower.