![OE Max Controls CSDP Plus User Manual Download Page 69](http://html1.mh-extra.com/html/oe-max-controls/csdp-plus/csdp-plus_user-manual_3398524069.webp)
71
Speed Control
Wiring
Speed Command
Set the speed command gain at SEt-01.
The setting range is 10 to 6000
RPM/1V or RPM/10V. The default value is 500.
The unit setting of SEt-01 is set up on the second
digit of SEt-46.
When the second
digit
of SEt-46 is 0
Speed Command
(RPM) = Speed Gain
(RPM/V) × Input Voltage
(V)
When
the second
digit
of SEt-46 is 1
Speed Command
(RPM) = Speed Gain
(RPM/10V) × Input Voltage
(V)