163
Open Collector Input
SEt-46(4) Speed Observer Selection
•
Setting range: 0 x 0 to 0 x 1
•
User Default: 0 x 0
•
Change while the servo is OFF, and turn off the power and turn it back on
The set values are as follows.
0: Use the embedded observation algorithm
1: Do not use the embedded observation algorithm
SEt-47 Notch Filter
•
Setting range: 0 to 10000 Hz
•
User Default: 10000
•
Changes anytime
This parameter suppress the torque command of setting frequency
area and vibration caused by resonance. The resonance frequency can
vary according to the load and if it is set properly, the system gain can
be raised more. If the newly-set frequency is different from the
resonance frequency of the load, vibration or noise can be generated.
SEt-48 Password
•
Setting range: 0 to 9999
•
User Default: 0
•
Changes anytime