142
SEt-18 In Speed/In Position Range
•
Setting range: 0 to 1000 RPM/pulse
•
User Default: 10
•
Changes anytime
This parameter is the error range of the speed or position that turns
ON the position completion signal (/P-COM). When the speed error or
position error reaches within the preset range,
/P-COM signal will be displayed.
If this parameter is high in the low-speed operation, the position
completion signal can be kept ON. This signal can usually be used as a
reference signal for the next sequence of the operation.
SEt-19 Acceleration Time
•
Setting range: 0 to 60000 ms
•
User Default: 200
•
Changes anytime
Acceleration time is the time required for the motor to reach the rated
speed from standstill.
The diagram shows that the time for execution compared to command
got extended as much as the deceleration time.