105
Please set the brake output waiting time at SEt-31.
The setting range is 0 to 1000 [10 ms] and the
default value is 50. This configuration is used for
the time for the motor brake to start working after
the controller delivered the servo
OFF command.
Brake Active Relay Time
Please set the brake output start speed at
SEt-30.
The setting range is 0 to 1000 RPM and the default
value is 100.
Braking Application Speed
If the brake active delay time is longer than the servo OFF delay time,
the brake works after the servo OFF is completed as shown below.
Then the vertial load is bound to fall for a moment by gravity.
ATTENTION
The brake mounted on the motor cannot be used to stop the
revolving motor. Please use it right before the stop or use it to
keep the stopped motor at a standstill.