background image

Wendy [email protected]

1

S2401 Instruction

Specification

1.Programmability: Non-programmable
2.Display Temperature Range

0°C~40°C (in 0.1°C increments)

3.Adjustable Temperature Range:5°C~35°C (in 0.5°C increments)
4.Temperature measurement accuracy:

±

1°C (at 20°C)

5.Power source: TX: 2x AAA 1.5V Alkaline Battery
6.Load Rating: 6(2)A, 230V

7.Low Battery Indicator: Display “

 

“ when battery is less than 2.7V

8.Standby current:25uA, Lighting current

5.5mA

9. Dimensions:

120 x 77 x 28 mm

LCD Display

Backlight

The backlight will be ON by turn the dial and OFF if no any operation for 15 seconds.

Manual Setting

1. Turn the dial in clockwise to increase the temperature, and then press the dial to confirm or wait for 5 seconds to
automatically confirm.
2. Turn the dial in anti-clockwise to reduce the temperature, and then press the dial to confirm or wait for 5 seconds
to automatically confirm.