BA_OTE 3+4_Endkunde_EN_V03_20170726.docx
Page 36 of 52
14
Building Management
There is the possibility to transfer the heating/cooling set value from a building manage-
ment system to the heat pump control. This set value can be transferred by means of a
0-10V DC signal and a switching contact for heating/cooling. The control can furthermore
send certain operational conditions to the building management system (e.g.: Heat pump
running, heat pump in cooling operation. If you wish to use this function, please contact
your nearest OCHSNER system partner.
15
Service-Report
15.1
Setting date and time
Settings procedure:
1.
Press
the adjustment knob in the main
display > the main menu appears
2.
Select the Service Report by
turning
the
adjustment knob and confirm by
pressing
the knob.
3.
By
turning
the adjustment knob, select
Settings
in the Service Report menu and
confirm this by
pressing
the knob.
4.
Select
Time
by
pressing
the adjustment
knob
5.
Set the time of day by
turning
the adjust-
ment knob and store this by
pressing
.
6.
> By repeated
pressing
of the ESC – knob
you return to the main display.
The automatic Summer-Winter time switch-over takes place on the last Sunday in Octo-
ber and on the last Sunday in March. By installing a room terminal with touch display, the
time of day can be automatically set on the OTE control. The date and time setting de-
scribed here is then of no effect.
ESC
02-072
SERVICE REPORT
Time
13:51
ESC
02-072
SERVICE REPORT
Time
13:51
SERVICE REPORT
Time
Date
Time program
Setpoint and actual values
ESC
ENTER
SERVICE REPORT
Master data
Error data
Passwort input
Settings
ESC
ENTER
Main menu
HEAT GENERATOR 2
HEAT MANAGER
CASCADE MANAGER
SERVICE REPORT
ESC
ENTER
Heating m ode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
3
5
1
2
4
6
The date can be set in the same way.