![Ochsner OTE 3 Operating Instructions Manual Download Page 31](http://html1.mh-extra.com/html/ochsner/ote-3/ote-3_operating-instructions-manual_723515031.webp)
BA_OTE 3+4_Endkunde_EN_V03_20170726.docx
Page 31 of 52
9
Auxiliary heater
An auxiliary heater (electro, oil or gas furnace) can be integrated into the heat pump sys-
tem. The auxiliary heater operation mode is set as follows:
Operation se-
lection
Description
0: Off
Auxiliary heater OFF (Auxiliary heater is then not available for charging
support (apart from frost protection/de-icing support))
1: Automatic
The auxiliary heater operates in automatic mode. Dependent on the
heat demand, the heat pump will be automatically switched on and off.
(recommended setting, switch in occurs only when the heat pump cannot
manage alone)
4: Manual
mode heating
Auxiliary heater heats to a fixed flow set temperature (09-020).
Attention:
This setting can lead to increased heating costs and should as
a rule only be used for short periods for commissioning/testing purpos-
es.
Settings procedure:
1.
Press
the adjustment knob in the main
display > the main menu appears
2.
Select the auxiliary heater by
turning
the
adjustment knob and confirm by
pressing
the knob. > the temperature image for the
auxiliary heater appears.
3.
In auxiliary heater temperature image, se-
lect the auxiliary heater menu by
pressing
the adjustment knob.
4.
By
turning
the adjustment knob, select
Operation mode selection
in the auxiliary
heater menu and confirm this by
pressing
the knob.
5.
Confirm the
operation mode heat genera-
tor
by
pressing
the adjustment knob
6.
Set the operation mode by
turning
the set-
tings knob and store by
pressing
, > repeat-
ed
pressing
of the ESC knob returns to
main display.
ESC
MENU
HEAT GENERATOR 2
ESC
ENTER
HEAT GENERATOR 2
09-075
Operation mode
1
09-020
Setpoint temper
0
HEAT GENERATOR 2
Operation mode heat genera-
tor
1: Automatic
ESC
09-075
Relay test
ESC
ENTER
HEAT GENERATOR 2
Operation mode
Operational data
Settings
Main menu
HEATING CIRCUIT 2
HOT WATER
HEAT PUMP
HEAT GENERATOR 2
ESC
ENTER
Heating m ode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
3
5
1
2
4
6