BA_OTE 3+4_Endkunde_EN_V03_20170726.docx
Page 16 of 52
5.10
Setting the cooling curve
Settings procedure:
1.
Press
the adjustment knob in the main
display > the main menu appears
2.
Select the Cooling circuit by
turning
the
adjustment knob and confirm by
pressing
the knob. > the temperature image for the
heating circuit appears.
3.
In heating circuit temperature image, se-
lect the heating circuit menu by
pressing
the adjustment knob.
4.
By
turning
the adjustment knob, select
settings
in the main menu and confirm this
by
pressing
the knob.
5.
By
turning
the adjustment knob, select
cooling curve
and confirm this by
pressing
the knob.
6.
In cooling curve temperature image, select
the cooling curve menu by
pressing
the ad-
justment knob.
7.
Select the
cooling setpoint temperature
by
pressing
the adjustment knob
8.
Change/adjust the parameter by
turning
the adjustment knob and store this by
pressing
. By repeated
pressing
of the ESC –
knob you return to the main display.
5.11
Setting the heating limit
By setting the heating limit, the
mean
outside temperature at which the heating circuit's
heating function is activated will be set. If the mean outside temperature is higher than
the set value, the heating function will not be released.
Please observe: "A difference of at least 5K must be given between the heating and cool-
ing limits!" Example setting: Heating limit =15°C and cooling limit =20°C
Settings procedure:
see section 5.12
03-043
HEATING CIRCUIT 2
Cooling setpoint temperature
cooling curve
17.0 °C
ESC
ESC
ENTER
03-048
Design supply t
17.0
HEATING CIRCUIT 2
03-043
Cooling setpoin 17.0
03-047
Design outside
32
HEATING CIRCUIT 2
ESC
MENU
17.0 °C Cooling curv e VLT
20 °C
17.0 °C
Outside temperature 32 °C
HEATING CIRCUIT 2
Heating curve
Target temperature cooling
Cooling curve
Configuration
ESC
ENTER
HEATING CIRCUIT 2
Operation mode
Operational data
Settings
Relay test
ESC
ENTER
HEATING CIRCUIT 2
ESC
MENU
Main menu
HEATING CIRCUIT 1
ESC
ENTER
HOT WATER
HEATING CIRCUIT 2
HEAT PUMP
Heating m ode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
1
2
3
4
5
6
7
8
All other cooling curve parameters can be adjusted in similar fashion.