INSTALLATION | Safety
24
www.ochsner.com | BIA-EUROPA Mini IWP-EN12
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1 General safety information
We guarantee trouble-free function and operational reliabil-
ity only if the original accessories and spare parts intended
for the appliance are used.
7.2 Regulations, provisions and standards
Note
Observe all applicable national and regional regu-
lations and provisions.
8. Device description
8.1 Scope of delivery
The scope of delivery of your appliance includes the fol-
lowing components.
►
Hot water heat pump EUROPA Mini IWP
►
2 wall brackets (525 mm height x 700 mm projection)
incl. rubber pads
►
Sensor pocket
►
3 cable temperature sensors
8.2 Heating coil
Connecting the heat pump to a coil is generally not permit-
ted! However, the heat pump can be connected if the coil
(heat exchanger) is appropriately sized.
9. Preparing to install the
appliance
Before installing the appliance, preparatory work needs to
be carried out by qualified contractors.
9.1 Installation location
Material damage
The intake air must not be contaminated with corro-
sive substances (ammonia, sulphur, chlorine, etc.)!
Machine components may be destroyed! The ap-
pliance is therefore not suitable for operation in
wine cellars, sewage treatment plants and animal
stables.
Material damage
The appliance is intended only for indoor instal-
lation. It must not be installed in rooms with high
levels of humidity (permanently above 70%).
The minimum room size for recirculation air-only mode is
30 m³. This value should also be taken into account if air
is drawn in from indoors and discharged to the outside.
Note
Please note: Not every installation room is the
same.
There are many influential factors that af
-
fect the minimum installation area and can even
increase it.
The following factors affect the minimum installation area:
►
Heating at the installation location
►
Level of air tightness in the installation room
►
Insulation in the installation room
►
Other heat generators in the installation room
►
Air short circuit between inlet and outlet
Note
»
If air is discharged to the installation room, in-
stall a 90° bend on the discharge opening and
turn it away from the intake opening to avoid
an air short circuit between inlet and outlet.
The installation location for the appliance must meet the
following requirements:
►
A dry and frost-free room
►
No lighting fixtures or pipes must be mounted above
the appliance.
►
Horizontal floor
►
Load bearing floor
►
Max. room temperature 40°C
Thanks to its lightweight design, it can also be wall mount-
ed (accessories).
One particularly effective method of