Sauna & Steam
Oceanic Saunas 01902 450 550 sales
@oceanic-saunas.co.uk www.oceanic-saunas.co.uk
16
Sauna Heater Manual
1.
Switch off power during any maintenance, or fitting electrical units.
2.
Do not hang clothes to dry in the heater, for this may cause a risk of fire.
3.
Do not bake food in heater.
4.
When it is hot, the outer surface of the heater may burn your skin.
1. Air supply vent
2. Optional air supply vent if mechanical exhaust ventilation is used, the opening is located 50cm
above the heater
3. Exhaust air vent
4. Drying vent, which is closed during heating and bathing, the sauna room can also be dried by
leaving the door open after bathing
5. If there is only an exhaust vent in washing room, leave an opening (MIN CM). Under the sauna
door (Mechanical ventilation is recommended)
9. Testing and Operation
9.1. 1. Testing
•
Before connecting to the power supply check the sauna heater and make sure there are
no flammable items on or around the heater, please note that on the first use the elements and
Fig 15
Model
Default Mode
Default Temp
o
C/
o
F
Temperature adjust scope
o
C
OC-SB
A
75
o
C
187
o
F
50-110
o
C
122-230
o
F
Default Time
Time adjust scope
Working time
Waiting
Work time
Wait time
2hrs
4hrs
10mins - 8hrs
0-12 hrs
Time adjustment per button press
Temperature adjustment per button
press
10 mins
1
o
C /2