background image

OUTDOOR PORTABLE AIR CONDITIONER

WITH AUXILIARY ELECTRIC HEAT

ENGINEERING, INSTALLATION AND SERVICE MANUAL

OCEANAIRE, Inc.
1731 Wall Street, Suite 100    Mount Prospect, IL    60056
(847) 583-0311    oceanaire-inc.com

OA-EISM-OPAC4212AH- REV. 04212023

Summary of Contents for OPAC4212AH

Page 1: ...AIR CONDITIONER WITH AUXILIARY ELECTRIC HEAT ENGINEERING INSTALLATION AND SERVICE MANUAL OCEANAIRE Inc 1731 Wall Street Suite 100 Mount Prospect IL 60056 847 583 0311 oceanaire inc com OA EISM OPAC421...

Page 2: ...AH unit As with all commercial air conditioning equipment it is recommended to have the OPAC4212AH sized and installed by a licensed specifying engineer and contractor in accordance with all local and...

Page 3: ...s are equipped with brakes for the securing the unit on site as well as for storage and transit The Power Connection Main Breaker and duct connections are all located on the left side of the unit for...

Page 4: ...OPTION 7 KW Electrical Heat ELECTRICAL Locking 250V Power Connection Receptacle 50 Amp Circuit Breaker for Unit Power Protection 40 Amp Auxiliary Heat Breaker 24 VAC Thermostat with 50 ft detachable...

Page 5: ...MAIN BREAKER BOX OPAC4212AH LEFT SIDE OPAC4212AH DETAILS THERMOSTAT STORAGE COMPARTMENT MAY BE LOCATED IN OTHER AREA OPAC4212AH REAR CONTROLS ACCESS PANEL EVAP BLOWER ACCESS PANEL THERMOSTAT CABLE REC...

Page 6: ...0 VAC Receptacle POWER INLET Hubbell CS8275 POWER CONNECTOR Hubbell CS8264C or Equivalent 6 Check that all power connections are secure and that the Main Breaker is ON up position 7 Connect Supply Pow...

Page 7: ...Number MODEL OPAC4212AH EVAP MOTOR POWER CONNECTOR PLF SEE NOTE 2 ON WIRING DIAGRAM EVAPORATOR BLOWER MOTOR TRANSFORMER COMPRESSOR CONTACTOR CAPACITOR THERMOSTAT CABLE RECEPTACLE OPAC4212AH CONTROLS O...

Page 8: ...OW VOLTAGE JUNCTION BOX FEMALE PLUG CONNECTOR IN HEATER BOX RUN CAPACITOR FOR COMPRESSOR AND FAN TRANSFORMER HIGH PRESSURE SWITCH NOTES 1 REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIG...

Page 9: ...pressing the SYSTEM button until the thermostat is in HEAT Mode Using the ARROW buttons set the desired space temperature setpoint Remember heating will begin once the space temperature has fallen 3...

Page 10: ...ed or wait until the space warms Check the incoming power for proper voltage plus the proper amperage to start the compressor If not contact an electrician Thermostat works Not Heating Check the therm...

Page 11: ...ubjected to any abnormal power conditions such as loss of power power surges voltage irregularities such as brown outs or phase loss on three phase equipment c any expenses including labor or material...

Page 12: ...OA EISM OPAC4212AH REV 04212023 OCEANAIRE Inc 1731 Wall Street Suite 100 Mount Prospect IL 60056 847 583 0311 oceanaire inc com NOTES...

Reviews: