Page 2: ...p Status 11 2 7 Configure the deployment 11 2 8 Begin recording using the IR Remote Control 13 2 9 Data Offload 14 3 More details 15 3 1 Data Files 15 3 2 Calculation of deployment endurance 16 3 3 De...

Page 3: ...4 1 3 User parameters 23 4 1 4 Output File formats 24 4 1 5 Click Detector Caveats and Cautions 25...

Page 4: ...tallation and basic deployment instructions This is followed by several sections containing more detailed information around operation deployment maintenance and troubleshooting It is highly recommend...

Page 5: ...se the lock screw by turning clockwise unit the screw bottoms out figure 1 Hold recorder with the hydrophone facing downward to ensure any remaining water won t run down into the housing Open the top...

Page 6: ...cking screw by means of a couple of turns of insulation tape figure 2 Replacement O Rings should be type 48x3 N70 Nitrile The O ring checks are critically important to avoid damage Any detritus or dam...

Page 7: ...r brands is unknown Untested brands may leak acid potentially causing damage to the electronics Source the batteries from reputable suppliers to avoid inferior counterfeits Be careful to ensure correc...

Page 8: ...card Any full or missing cards will be skipped 3 It is critical that each card is formatted prior to each deployment This can only be done in the SoundTrap recorder using the Delete All Files option...

Page 9: ...ted the SoundTrap host software installation o The installation will be smoother if you re logged into windows as an administrator Visit www OceanInstruments co nz downloads to download the software D...

Page 10: ...Figure 3 The Device List...

Page 11: ...gure 4 Deploy Control 2 7 Configure the deployment Select the Deploy tab as shown in figure 4 Configure the deployment parameters as follows o The Recording Starts section determines when recording wi...

Page 12: ...re 1 uPa The Low setting should be used for very noisy environments such as in the vicinity of pile driving The low setting increases the maximum SPL to around 187 dB but comes at the cost of lower s...

Page 13: ...ART to start recording Press STOP to stop recording If you have set a recording to start recording at a later time the recorder will blink red to indicate it is armed and waiting The armed state is ca...

Page 14: ...date recorded approximate size and whether it has yet been downloaded to your computer s hard drive Download individual files by right clicking the file and selecting download By default all files wil...

Page 15: ...t can be opened by any media player matlab raven etc o xml files which contain metadata such as date recorded gain setting etc o csv files containing ancillary sensor data e g temperature All file typ...

Page 16: ...y has a minimum file size of 4 MB When using periodic recording if the programmed record for a period of period is very short the resultant file may be smaller than the minimum file size This will res...

Page 17: ...of the housings below the locking screw Avoid using the hydrophone cage as an attachment point This is too close to the hydrophone and will likely introduce unwanted noise into the recordings Be mindf...

Page 18: ...tware as well as the device firmware The updating of the device firmware is an automatic process that occurs when pressing the deploy button 3 6 MSP firmware updates From time to time a software relea...

Page 19: ...will proceed and complete within a few seconds If presented with the error message MSP Erase failed it is likely that the pressing of the reset button was interrupted please try again...

Page 20: ...tivity in voltage terms Because SoundTraps integrate the recorder and hydrophone in a single package there is a fixed relationship between sound pressure and the resultant wav file data thereby simpli...

Page 21: ...kHz tone should be equal to the calibration tone level stated on the calibration sheet If the calibration tones are an annoyance they can be disabled on the deploy tab However we recommend keeping th...

Page 22: ...Impulse Response FIR filter approximate 3 dB bandwidth 115 160 kHz followed by a moving average power estimator The duration of the moving average window is a user parameter see below In parallel the...

Page 23: ...g time of 150 300 s would be appropriate If you are interested in detecting any toothed whale click you can either go with a long averaging time which will reduce the SNR of short transients and so gi...

Page 24: ...but this is transparent to the user the wav file contains the reconstituted uncompressed data dwv This is a Microsoft WAV format file containing the wideband sound snippets for each detection The samp...

Page 25: ...ibels i e 100 log10 p where p is the noise power referenced to the recorder calibration The absolute threshold used for each detection is then p 10 RDT 10 If no detections were made throughout a recor...