Read this owner’s manual thoroughly
before operating the appliance and keep
it handy for reference at all times.
OBZ-06CR3
Page 1: ...Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times OBZ 06CR3...
Page 2: ...aintenance or have problems installing the unit If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Inside...
Page 3: ...nts It may cause an electric shock Do not allow water to come into contact with any electric parts It may cause failure or electric shock Do not use a power outlet or a power cord if it s loose or dam...
Page 4: ...may enter the unit and degrade the insulation which could lead to electric shock Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or harm the plan...
Page 5: ...ve chosen This information can be found on the serial plate which is located on the side of the cabinet and behind the grille If the air conditioner is to be installed in a window you will probably wa...
Page 6: ...ed assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification NOTE Do not use this device to turn the unit...
Page 7: ...rant R32 is used in air conditioner Please follow the instruction carefully to avoid any hazard IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit...
Page 8: ...ried out Work in confined spaces shall be avoided The area around the workspace shall be sectioned off Ensure that the conditions within the area have been made safe by control of flammable material 4...
Page 9: ...t to being corroded or are suitably protected against being so corroded 9 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component...
Page 10: ...ked flame shall not be used 11 Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used t...
Page 11: ...e shall be taken not to overfill the refrigeration system Prior to recharging the system it shall be pressure tested with OFN The system shall be leak tested on completion of charging but prior to com...
Page 12: ...ted shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instr...
Page 13: ...NOTE The following instructions represent the control panel on the unit the same instructions can be used for the remote control ADJUSTS TEMPERATURE OR TIME ACTIVATES TIMER CHECK FILTER RESET BUTTON...
Page 14: ...mode On DRY mode the fan speed is set to LOW automatically To select mode press the Mode button Each time you press the button the mode will change based on the sequence from AUTO COOL DRY and FAN The...
Page 15: ...selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the SLEEP...
Page 16: ...Filter for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off Press or hold...
Page 17: ...c 3 minute time delayed start if the unit is turned off and on too abruptly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this t...
Page 18: ...these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical skills Completion time Approxima...
Page 19: ...place it the top rail of the unit...
Page 20: ...n a floor a bench or a table Be sure that the left and right window filter panels are on the proper side When installed the flange for securing the panel in place to the window sill should be facing i...
Page 21: ...unit see Fig 13 Keep a firm grip on the air conditioner carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill Fig 5 Carefully close the...
Page 22: ...ccumulated Rain Water or Condensation must be allowed to drain out Turn the AC off and disconnect the power cord Remove sash seal from between windows and unscrew safety lock Remove screws installed t...
Page 23: ...er use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and...
Page 24: ...ilter as instructed on the CLEANING AND MAINTENANCE SECTION of this manual The temperature may be set too high Set the temperature control to a lower setting Air directional louvers may be positioned...
Page 25: ...low water to drain out Refer to the HOW TO INSTALL section on page 19 or check with the person who installed the unit initially The noise may be due to window vibration This can happen when the air co...
Page 26: ...sound of rushing air being moved by the fan High Pitched Sound High efficiency compressors may have a high pitched sound during the cooling cycle Vibration The unit may vibrate and make noise because...