background image

SLIMFOCUS: 

MODEL SPECIFICATIONS

1. TECHNICAL DATA 

2

2. PRE-INSTALLATION 

3

3. INSTALLATION 

5

4. OPERATION 

13

5. TESTING 

14

Keep for future use

Summary of Contents for FOCUS SERIES

Page 1: ...SLIMFOCUS MODEL SPECIFICATIONS 1 TECHNICAL DATA 2 2 PRE INSTALLATION 3 3 INSTALLATION 5 4 OPERATION 13 5 TESTING 14 Keep for future use ...

Page 2: ... TECHNICAL DATA DETERMINED UNDER TEST CONDITIONS Nominal thermal output 9kW Efficiency Australian Test 60 Emissions Australian Test 1 4 g Kg 575 245 655 2070 324 WEIGHT AND DIMENSIONS Dimensions Firebox O 324mm Firebox weight 180kg Flue kit Standard 6 8 10 ...

Page 3: ...ernal flue and engage the firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation If such action is necessary consult the manufacturer in the first instance WARNING The appliance and flue system must be installed in accordance with AS NZS ...

Page 4: ... with the application of heat shielding to walls in accordance to the Australian Building Code For information on heat shielding please contact our office on 03 9416 0400 or email info oblica com au IMPORTANT Frames must also be considered Timber window frames must be treated as combustible surfaces see 2 3 Aluminium frames can be treated as non combustible surfaces see 2 2 2 PRE INSTALLATION CONT...

Page 5: ...n bracket The bracket must be structurally secured within the roof as shown in the diagram below The largest cylinder must project down from the ceiling by at least 150mm to connect with lower section You must leave a 25mm clearance gap between the bracket and the ceiling This gap will be covered by the ceiling Flange 12mm ventilation gap between the plasterboard and the ceiling flange 25mm minimu...

Page 6: ...PAGE 6 OBLICA SLIMFOCUS INSTALLATION AND USER MANUAL 3 INSTALLATION CONTINUED Custom Length Angle 1 2 25 150 PITCHED ROOF INSTALLATION CUSTOM MADE BRACKET ...

Page 7: ...PAGE 7 OBLICA SLIMFOCUS INSTALLATION AND USER MANUAL 3 INSTALLATION CONTINUED ...

Page 8: ...PAGE 8 OBLICA SLIMFOCUS INSTALLATION AND USER MANUAL 3 INSTALLATION CONTINUED ...

Page 9: ...Chinaman Hat 8 Outer Case 10 Outer Case 8 Outer Case 10 Outer Case 6 Active Flue 8 Flue CEILING RING RUBBER DEKTITE FLASHING 3 1 Installing flue kit Ensure flue is installed as per Australian standards see the following diagrams below 3 INSTALLATION CONTINUED ...

Page 10: ...oof Alternatively there must be a minimum distance of 3 meters from any higher section of roof 40 cm 40 cm 40 cm 3 m 900 cm 3 m 900 cm 900 cm The top of the flue must be 900mm above the roofline Alternatively there must be a minimum distance of 3 meters from any higher section of roof PITCHED ROOF INSTALLATION FLAT ROOF INSTALLATION LESS THAN 5 PITCH ...

Page 11: ...tiles steelsheet lightconcrete etc If the combustible floor is installed on concrete you can replace the combustible material with non combustible material laid directly onto the concrete Joist Insulative board 9mm non combustible finish Combustible floor eg timber FLOOR PROTECTOR LAID ON TIMBER FLOOR 3 INSTALLATION CONTINUED Joist Insulative board 9mm non combustible finish Combustible floor eg t...

Page 12: ... Combustible floor eg Timber Floor protector 300mm 300mm 300mm 300mm 925mm 925mm Combustible floor eg Timber Floor protector 3 INSTALLATION CONTINUED TOP VIEW TOP VIEW Minimum floor protector size in a non rotating configuration Minimum floor protector size in a rotating configuration ...

Page 13: ...ls to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of some types of preservative treated woods as a fuel can be hazardous IMPORTANT Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee The maximum l...

Page 14: ...15 INVESTIGATING OFFICER Steve Marland RESULTS CONCLUSION The SlimFocus solid fuel burning appliance produced an appliance particulate emissions factor of 1 4k kg and an average efficiency of 60 for all burn rates using hardwood that complies to AS NZS4014 1 when tested according to joint AS NZS 4012 AS NZS 4013 2014 The SlimFocus solid fuel burning appliance complies with the requirement of a com...