OBID
®
Manual
ID RW01L.AB-A
FEIG ELECTRONIC GmbH
Page 35 of 39
H20801-1e-ID-B.doc
5.1.6. D_START
This parameter defines the first byte of the raw data (defined by DB_ADR and D_LGT) which should
be sent in scan mode. If you want to output a complete block, D_START = 0 must be set.
5.1.7. SCAN_PREFIX
This parameter is used to define any desired start character for scan mode over the asynchronous
interface.
As soon as the reader outputs data in scan mode over the asynchronous interface and the bit
PREFIX_E = 1 is set (see:
), this character is prefixed to the data stream.
5.1.8. SCAN_TERM
This parameter is used to define any desired terminating character for scan mode over the
asynchronous interface.
As soon as the reader outputs data in scan mode over the asynchronous interface and the bit
TERM_E = 1 is set (see:
), this character is appended to the data stream.
5.1.9. TAG_DRV
This parameter is used to exclusively define which transponder model is processed. The reader will
only process the transponder model configured here (or compatible derivative versions of this model).
TAG_DRV:
0:
ID CTx.A (read-only)
1:
ID DTx.B (read / write)