OBERON TCG Series User Manual Download Page 3

OBERON USER GUIDE  

Arc Flash Suit Care & Use 

 

 

 

 

 

TCG Series | Rev 2 

Oberon Introduction: 

 
Oberon is the leading arc flash personal protective equipment (PPE) manufacture in the World. 
Located in New Bedford, Massachusetts,  USA, Oberon manufactures arc-rated products used for 
protection from  arc flash hazards. Oberon products are designed to help workers by keeping them 
safe and improving human performance using ultra-lightweight arc-rated fabrics and innovative shield 
technologies including its True Color Grey (TCG) faceshields and suit hood shield windows. Oberon 
has engineered its arc flash PPE to be the safest available products on the market.   
  

Care & Use Training:   

 
Standards for electrical safety in the workplace including NFPA 70E and CSA Z462 require care and 
maintenance of arc-rated clothing and arc-rated arc flash suits. Employers shall provide care and use 
training to any worker that needs arc flash PPE.  
 
Arc flash PPE training requirements include:  

  Sizing & Selection. 

  Pre-Use Inspection. 

  How to Wear an Arc Flash Suit. 

  Manufacturer’s Instructions.  

  Storage. 

  How to Disassemble/Assemble an Arc Flash Suit Hood. 

  Cleaning & Repairs.  

 

Caution: 

 
Flammable contaminants will reduce the thermal performance of any flame resistant arc-rated 
garment. Wash garments to ensure that no greases, oil, soiling or other flammable contaminants are 
present when the garments are worn. Arc flash suits are engineered using multiple layers of fabric so 
if the garment becomes damaged only the manufacture can make repairs. 
 

Do not reuse Oberon arc flash PPE after an arc exposure. 

 

 

Important Warning: 

 
Oberon arc flash suits are designed for arc flash protection and do not provide insulation (protection) 
from electric shock. Oberon arc flash suits when properly selected and worn are designed to provide 
protection from burn injuries resulting from an electrical arc flash in accordance with ASTM F1506 & 
NFPA 70E/CSA Z462 Standards. It is important to note that Oberon arc flash suits will provide limited 
or no protection against sound, pressure, projectiles and respiratory hazards which may result from 
an arc flash incident. Face protective products which are effective against the arc flash hazard can 
reduce visibility. NFPA 70E/CSA Z462 calls for the use of additional lighting if work conditions require. 
 
 
 

Summary of Contents for TCG Series

Page 1: ...OBERON USER GUIDE Arc Flash Suit Care Use 1 TCG Series Rev 2 Oberon s TCG Series Arc Flash Suits Jim Pollard Canadian Sales Manager Oberon Company 519 939 3204 jim oberoncompany com www arcflash com...

Page 2: ...mportant Warning 3 Remember 4 Compliance 4 Arc Flash Suit Hood Specification 4 Arc Flash Suit Coat Bib Overall Specification 4 Sizing Selection 5 Pre Use Inspection 5 How to Wear an Arc Flash Suit 6 I...

Page 3: ...tructions Storage How to Disassemble Assemble an Arc Flash Suit Hood Cleaning Repairs Caution Flammable contaminants will reduce the thermal performance of any flame resistant arc rated garment Wash g...

Page 4: ...shield window made of polycarbonate material providing high impact and high mass protection for maximum protection from shrapnel projectiles and flying debris ANSI Z87 1 Certified Anti scratch coating...

Page 5: ...zes short tall and extra tall When using a sizing kit it s important to make sure you have the same PPE on that you would when using the suit Don t wear street clothing during sizing If you intend on...

Page 6: ...not broken These parts are made with plastic so if they break it s easy to buy replacements Inspect the fabric inside and out to make sure it s not ripped frayed no holes any damage or contamination F...

Page 7: ...it doesn t fit right do not proceed to wear it The FR knit cuffs should fit to your wrists The pant leg bottoms should be long enough to completely cover your legs down to your ankles You re only as w...

Page 8: ...tures instructions At the back of the hood remove the fan unit by twisting the hose coupling to the left detach the fan remove the fan pack from the mounting strap and then place it aside Pay attentio...

Page 9: ...e hood pull the FR hose out the port hole There is a protective flap inside the hood so find the top and pull the hose down Reach around on the outside at the back and pull the coupling and hose throu...

Page 10: ...ould become plugged by lint If this has already happened comb out the hook side of the FR Velcro Follow the Oberon label for instructions on how to properly launder your suits General cleaning require...

Page 11: ...ase Dry cleaning shall be done according to the care labeling by usual 2 bathprocedure Boosters should only be used in extreme situations and only with reduced mechanism Dry cleaning shall only be don...

Reviews: