![OBERON 1006-CCOAP Installation Instructions Download Page 1](http://html1.mh-extra.com/html/oberon/1006-ccoap/1006-ccoap_installation-instructions_721452001.webp)
Installation Instructions
Model Number 1006-CCOAP
(877) 867-2312
•
www.oberonwireless.com
P/N 2593 – Rev. 1 12/22/2015
Oberon, Inc.
•
••
•
1315 South Allen Street
•
••
•
State College, PA 16801
Copyright 2015
Assembly Components:
- Right angle wall mount – 1 each
- Access point mounting bracket – 1 each
- Acorn nuts - 2 Each
- #8 - 32 screws (for attaching access point mounting plate) – 4 each
- Installation Instructions – 1 each
If any of these items are missing, contact your Oberon representative.
Step 1 - Determine the location where the
Cisco access
point
will be installed. Ideally, the location should be in an
area where the mounted access point will be free of
obstructions and high up on the wall.
Step 2 - If feasible, an Ethernet wall outlet should be pre-
installed where the
Oberon Model 1006-CCOAP right angle
wall mount
and
Cisco access point
will be placed. This will
allow for the most aesthetic installation, free of distracting
cables. If a wall plate cannot be installed due to the wall
construction, alternatively, a race way can be installed to
bring the Ethernet cable to the mounting location.
Step 3 - Install the
Oberon right angle wall mount
to the wall
using proper mounting screws based on the construction of
the wall surface (customer supplied). The
Oberon right angle
wall mount
should ideally be placed so that the open area of
the wall mount is located directly over top of the wall plate
(Ref. figure 1).
**IMPORTANT**
-
It is important that the right angle
mount is securely fastened to the wall to prevent human
injury or damage to the access point.
Page 2
Once the
Oberon right angle wall mount
has been
secured to the wall, find a flat work surface to
assemble the
Cisco
access point
to the
Oberon
access point mounting bracket
prior to mounting on
wall.
Step 4 – Place the
Oberon access point mounting
bracket
on the work surface.
Step 5 - Attach the
Cisco mounting plate
to the
Oberon
access point mounting bracket
using the
four (4) #8-32 screws provided. The
Cisco mounting
plate
should be aligned with the
Oberon
access
point mounting bracket
so that the cable entry on the
Cisco mounting plate
is positioned toward the cutout
of the Oberon
access point mounting bracket
(
Ref.
Figure 2
).
Step 6 - Determine the required length Ethernet jumper (the jumper should be as short as possible to minimize the amount of
cable visible after installation) and attach one end of the cable to the
Cisco access point
.
Step 7 – After the Ethernet cable has been attached to
the
Cisco access point
, attach the
Cisco access point
to
the
Oberon access point mounting bracket/Cisco
mounting bracket
assembly (
Ref. figure 3
).
The
access point assembly
is now ready to be attached
to the
Oberon right angle wall mount
.
Page 3
Figure 2
Figure 1