OBERON 1006-CCOAP Installation Instructions Download Page 1

Installation Instructions 

Model Number 1006-CCOAP 

(877) 867-2312

   

   

www.oberonwireless.com 

P/N 2593 – Rev. 1 12/22/2015

 

Oberon, Inc.  

••

  1315 South Allen Street  

••

  State College, PA 16801 

Copyright 2015

 

 
 
 

Assembly Components: 

- Right angle wall mount – 1 each 
- Access point mounting bracket – 1 each 
- Acorn nuts - 2 Each 
- #8 - 32 screws (for attaching access point mounting plate) – 4 each 
- Installation Instructions – 1 each 
 

 
If any of these items are missing, contact your Oberon representative. 
 
 
 
 
Step 1 - Determine the location where the 

Cisco access 

point

 will be installed.  Ideally, the location should be in an 

area where the mounted access point will be free of 
obstructions and high up on the wall.  
 
 
 
 
Step 2 -  If feasible, an Ethernet wall outlet should be pre-
installed where the 

Oberon Model 1006-CCOAP right angle 

wall mount

 and 

Cisco access point

 will be placed. This will 

allow for the most aesthetic installation, free of distracting 
cables. If a wall plate cannot be installed due to the wall 
construction, alternatively, a race way can be installed to 
bring the Ethernet cable to the mounting location. 
 
 
 
 
Step 3 - Install the 

Oberon right angle wall mount

 to the wall 

using proper mounting screws based on the construction of 
the wall surface (customer supplied). The 

Oberon right angle 

wall mount

 should ideally be placed so that the open area of 

the wall mount is located directly over top of the wall plate 
(Ref. figure 1). 
 
 
 
 

**IMPORTANT**

  - 

It  is  important  that  the  right  angle 

mount is securely fastened to the wall to prevent human 
injury or damage to the access point.

 

 

 

 
 
 
 

Page 2 

 
 
 
 
 
Once the 

Oberon right angle wall mount

 has been 

secured to the wall, find a flat work surface to 
assemble the 

Cisco

 

access point 

to the 

Oberon 

access point mounting bracket 

prior to mounting on 

wall. 
 
 
Step 4 – Place the 

Oberon access point mounting 

bracket 

on the work surface. 

 
 
 
Step 5 - Attach the 

Cisco mounting plate

 to the 

Oberon

 

access point mounting bracket

 using the 

four (4) #8-32 screws provided. The 

Cisco mounting 

plate

 should be aligned with the 

Oberon

 

access 

point mounting bracket

 so that the cable entry on the

 

Cisco mounting plate

 is positioned toward the cutout 

of the Oberon 

access point mounting bracket

 (

Ref. 

Figure 2

). 

 
 
 
Step 6 - Determine the required length Ethernet jumper (the jumper should be as short as possible to minimize the amount of 
cable visible after installation) and attach one end of the cable to the 

Cisco access point

 
 
 

 
 
 
 
Step 7 – After the Ethernet cable has been attached to 
the 

Cisco access point

, attach the 

Cisco access point

 to 

the 

Oberon access point mounting bracket/Cisco 

mounting bracket 

assembly (

Ref. figure 3

). 

 
 
 
 
 
The 

access point assembly

 is now ready to be attached 

to the 

Oberon right angle wall mount

 
 
 
 

 
 
 

Page 3 

 

Figure 2     

 

Figure 1     

 

Figure 3 

 

Reviews: