1  ABOUT THIS PRODUCT 

 
Obelux MI compact series LED obstruction lights provide 2,000cd color aviation red light and Night Vision 
Goggle (NVG) compliant infrared (850 nm) light. Both Stand-alone and Modbus operation are supported. In 
Stand-alone mode, no external controllers are required to run the light. In Modbus operation, the light is 
controlled with an Obelux controller as a part of an aviation light system. 
 
Features: 
► Fault monitoring with dry contact alarm relay 
► Photocell 
► GPS synchronization 
► Support for operating in cold climates 
► Visibility sensor interface controlled luminous output levels (10%, 30%, and 100%) 
► Hot start for radar-controlled systems 
► Easy to chain (no need for junction box) 
► Embedded Web Server 
Optional Controllers: 
► CP Series (Interfaces: Ethernet TCP/IP and RS-485/Modbus, AC or DC) 
► CP-M1 Series (Interface: RS-485/Modbus, AC or DC) 

1.1  ICAO models product codes 

Order code 

Output 

ICAO 

Operating 
voltage 

Nominal 
voltage 

GPS 

IR 

Heater 
(CCV) 

PC 

Alarm 
relay 

RS-485 
Modbus 

MI-ICAO-AC-2KR-IR-B[-10] 

2 000 / 
200 cd 

Type 
B/C 

100-240VAC 

 

No 

Yes 

Yes 

Yes 

Yes 

No 

MI-ICAO-AC-2KR-IR-X [-10]

 

2 000 / 
200 cd

 

Type 
B/C 

100-240VAC 

 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

MI-ICAO-DC-2KR-IR-B[-10] 

2 000 / 
200 cd

 

Type 
B/C 

10-60VDC 

 

No 

Yes 

Yes 

Yes 

Yes 

No 

MI-ICAO-DC1224-2KR-IR-X[-10]

 

2 000 / 
200 cd

 

Type 
B/C 

10-30VDC 

12/24VDC 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

MI-ICAO-DC2448-2KR-IR-X[-10] 

2 000 / 
200 cd

 

Type 
B/C 

20-60VDC 

48VDC 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

MI-ICAO-AC-2KR-IR-E1-B[-10] 

2 000 / 
200 cd

 

Type 
B/C 

100-240VAC 

 

No 

Yes 

Yes 

Yes 

Yes 

No 

MI-ICAO-AC-2KR-IR-E1-X[-10] 

2 000 / 
200 cd

 

Type 
B/C 

100-240VAC 

 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

MI-ICAO-DC-2KR-IR-E1-B[-10] 

2 000 / 
200 cd

 

Type 
B/C 

10-60VDC 

 

No 

Yes 

Yes 

Yes 

Yes 

No 

MI-ICAO-DC1224-2KR-IR-E1-X[-10] 

2 000 / 
200 cd

 

Type 
B/C 

10-30VDC 

12/24VDC 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

MI-ICAO-DC2448-2KR-IR-E1-X[-10] 

2 000 / 
200 cd

 

Type 
B/C 

20-60VDC 

48VDC 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

B[-10]:  B = basic model  

 

X[-10]:  IO = 4x Input and 4x Output (IO) Interface 

10 = 10-year warranty   

 

EF = Ethernet Switch, 2x fiber SC multimode Female, 2x 
copper RJ-45 
E = 1x Ethernet copper RJ-45 
10 = 10-year warranty 

E1 = these product variants fulfil also the -1° and -10° vertical elevation angles maximum intensities 
requirements 
 
Available mounting set options: 
MS-MI-H01 (mounting bracket as AISI304 acid-proof stainless steel, nuts and bolts A4 steel) 
MS-MI-H02 (mounting bracket as AISI316 acid-proof stainless steel, nuts and bolts A4 steel) 
MS-MI-V01 (mounting set as AISI316 acid-proof stainless steel, nuts and bolts A4 steel) 

Summary of Contents for Medium-Intensity 2000cd compact Series

Page 1: ...Obelux Medium Intensity 2000cd compact series manual Medium intensity 2 000cd red aviation obstruction light ICAO Medium Intensity Type B C FAA L 864 L 885 NVG Compliant Infrared 850nm...

Page 2: ...ALLATION 10 3 1 DEVICE INSTALLATION 10 3 2 WIRING 10 3 2 1 Mains In Out AC versions 11 3 2 2 DC In Out DC versions 11 3 2 3 Modbus RS 485 In Out 11 3 2 4 Alarm Relay Output 11 3 2 5 Chaining Lights 12...

Page 3: ...Author 0 1 02 01 2020 Document created JSi 1 0 19 05 2020 Release JSi 1 1 05 10 2020 Updated product codes heater JSi Acronyms and Abbreviations FAA Federal Aviation Administration FPM Flashes Per Mi...

Page 4: ...s Yes Yes Yes No MI ICAO AC 2KR IR X 10 2 000 200 cd Type B C 100 240VAC Yes Yes Yes Yes Yes Yes MI ICAO DC 2KR IR B 10 2 000 200 cd Type B C 10 60VDC No Yes Yes Yes Yes No MI ICAO DC1224 2KR IR X 10...

Page 5: ...5 100 240VAC Yes Yes Yes Yes Yes MI FAA DC 2KR IR B 10 2 000cd L 864 L 885 10 60VDC No Yes Yes Yes No MI FAA DC 2KR IR X 10 2 000cd L 864 L 885 10 60VDC Yes Yes Yes Yes Yes B 10 B basic model X 10 IO...

Page 6: ...notice 1 3 Product highlights Figure 1 Main functional parts of light head 1 Location of photocell and GPS do not cover 2 Spirit level 3 Location of cable glands M20 2 pcs M25 2 pcs Factory installati...

Page 7: ...Medium Intensity 2000cd compact series manual Page 7 of 21 Obelux Oy 2020 Technical information in this document is subject to change without notice Figure 2 Main PCB of a light head AC version...

Page 8: ...Medium Intensity 2000cd compact series manual Page 8 of 21 Obelux Oy 2020 Technical information in this document is subject to change without notice Figure 3 Main PCB with E EF and IO add on cards...

Page 9: ...n issued directive 2012 19 EU to contribute to sustainable production and consumption by as a first priority the prevention of WEEE and in addition by the re use recycling and other forms of recovery...

Page 10: ...size cable glands used on the device M25 cable glands for 6 17 mm cable diameter and M20 cable glands for 6 12 mm cable diameter Make sure that all unused glands or gland holes are sealed Figure 4 Dim...

Page 11: ...into this pole GND Ground Connect the power supply ground wire into this pole The connectors are Wago Push in CAGE CLAMP type Conductor cross section 0 2mm 4mm 24 12 AWG Recommended conductor size 2 5...

Page 12: ...s Figure 6 Chaining light heads Figure 7 Distributing power and data to next light head of the network AC version Figure 8 Distributing power and data to next light head of the network DC version When...

Page 13: ...changing between the modes Stand alone mode In this mode the light operation is configured with its DIP switches No additional controllers are needed Light head will use its internal photocell to det...

Page 14: ...ing mode based on ambient luminosity DIP switch Photocell mode 6 off Photocell is disabled on Photocell controls the light Turn DIP7 on for correct operation DIP switch Master Slave mode 7 off This de...

Page 15: ...cell mode 6 off Photocell is disabled on Photocell controls the light DIP switch Master Slave mode 7 off This device is slave on This device is master DIP switch Operating mode 8 off Stand alone on Mo...

Page 16: ...s disabled on Photocell controls the light Turn DIP7 on for correct operation DIP switch Master Slave mode 7 off This device is slave on This device is master must be on Turn DIP8 off for correct oper...

Page 17: ...d alone on Modbus Factory default 4 3 Modbus mode The light is in Modbus mode when DIP8 is on Light is being controlled with an Obelux controller DIP switch Operating mode 8 off Stand alone on Modbus...

Page 18: ...rning on the termination DIP switch on both ends of the communications bus 4 4 Test mode To enter test mode set DIP7 and DIP8 on and all other DIPs off The light will enter test mode when power is tur...

Page 19: ...Set a lamp to master mode by switching its DIP7 on Set DIP7 off in the slave lamps to put them to slave mode DIP switch Master Slave mode 7 off This device is slave slaves on This device is master mas...

Page 20: ...OWER Internal operating voltage GREEN LED OFF Unit has power off LED ON Unit has power on COM Communication GREEN LED OFF Waiting for external signals LED FLASHING Master slave communications occurrin...

Page 21: ...re averaged to avoid sudden state changes Unless test mode is enabled it takes approx three 3 minutes to change system state between day twilight and night Light does not flash in sync GPS antenna is...

Reviews: