4.2.2 FAA Stand-alone mode
DIP switch
Flash rate (FPM)
4
5
off
off
20
on
off
30
*
off
on
40
on
on
60
DIP switch
Photocell mode
6
off
Photocell is disabled
*
on
Photocell controls the light
DIP switch
Master/Slave mode
7
off
This device is slave
*
on
This device is master
DIP switch
Operating mode
8
off
Stand-alone
*
on
Modbus
* Factory default
4.3 Modbus mode
The light is in Modbus mode when DIP8 is on. Light is being controlled with an Obelux controller.
DIP switch
Operating mode
8
off
Stand-alone
on
Modbus
Configuration DIP switches 1-4 are used to give the light a RS-485 bus address. Duplicate addresses on the
same bus are not allowed. Give lights connected to the same communication bus an address starting from
address one.
DIP switch
Flashing mode
1
2
3
Night
off
off
off
2,000cd red and infrared (flashing)
*
on
off
off
2,000cd red (flashing)
off
on
off
Reserved
on
on
off
Reserved
off
off
on
Reserved
on
off
on
Reserved
off
on
on
Reserved
on
on
on
Reserved