background image

 

 © Obelux Oy 2016                                                                                                     Technical information in this document is subject to change without notice.  

Page: 1(17) 

 

OBELUX

A V I A T I O N  L I G H T S

 

 

 

 

 

 

OBELUX CSW-DCW 

Fault monitoring, switch-over and flash controller unit 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual 

Version 1.1 

 

 

Summary of Contents for CSW-DCW

Page 1: ...016 Technical information in this document is subject to change without notice Page 1 17 OBELUX A V I A T I O N L I G H T S OBELUX CSW DCW Fault monitoring switch over and flash controller unit Manual...

Page 2: ...2 1 DC power input 9 5 2 2 Outputs 1 4 9 5 2 3 Alarm relay output 9 5 2 4 GPS External Antenna 9 6 CONFIGURATION 10 6 1 BASE SEQUENCE 10 6 2 FLASH DURATION 11 6 3 FLASH MODE 11 6 4 TEST MODE 11 6 5 P...

Page 3: ...lux Oy 2016 Technical information in this document is subject to change without notice Page 3 17 1 CHANGE LOG Version Date Description Author 0 1 24 03 2016 Document created AHa 1 0 07 07 2016 Documen...

Page 4: ...to change without notice Page 4 17 2 ABOUT THIS DOCUMENT This document describes the installation and setup of the CSW DCW unit DIP switch effects and operation of the unit on practical level CPU Cen...

Page 5: ...ndividual channels with dial switches In addition to sending an alarm via dry contact the CSW DCW can drive backup light s during master light outage CSW DCW is microprocessor controlled Application s...

Page 6: ...n Union issued directive 2012 19 EU to contribute to sustainable production and consumption by as a first priority the prevention of WEEE and in addition by the re use recycling and other forms of rec...

Page 7: ...mation in this document is subject to change without notice Page 7 17 5 INSTALLATION 5 1 Device installation Mount the CSW device to the selected mounting point using quality made fasteners When the c...

Page 8: ...are two different size cable glands available on the cabin Make sure that unused glands and gland holes are plugged shut Cable gland 5 x M25 for 13 18 mm cable diameter Cable gland 2 x M16 for 4 5 10...

Page 9: ...connector Unused output connectors can be left floating i e no wiring there is required They shall not be short circuited Tighten connectors securely using flat head straight screwdriver Conductor cro...

Page 10: ...here is no valid configuration the CSW DCW uses configuration where all DIP switches are set to OFF This configuration disables all channels Figure 2 DIP switches in off position 6 1 Base sequence DIP...

Page 11: ...uts off off All enabled outputs flash together 6 4 Test mode DIP switch named TEST MODE selects the test mode Test mode makes CSW DCW system testing easier Set the test mode DIP switch to ON to enter...

Page 12: ...he RS485 bus This functionality is not covered in this manual 6 9 Alarm windows All four channels have their own rotary switch dials to select minimum and maximum alarm limits Alarm window is selected...

Page 13: ...hold where low intensity lights are turned off Flashing frequency is selected 40 flashes minute and flash duration 100ms In this example Lamp1 and Lamp3 are main lamps Lamp2 and Lamp3 are spare If Lam...

Page 14: ...on CASA Flash duration Duty cycle 2 3 ON 1 3 OFF 6 7 6 7 Flashing mode off off All active Outputs flash together off on Outputs 1 3 are flashing together output 4 is steady burning 8 8 Test mode enab...

Page 15: ...t is checked for short circuit If short circuit is detected the output channel light is disabled and an alarm is raised Also whenever a light is illuminated the current this obstacle light draws from...

Page 16: ...its the ON LED will turn orange In this case the power alarm window should be adjusted so that unnecessary alarms can be avoided Normally the ON LED is green 7 6 2 GPS alarm When the CSW powered up th...

Page 17: ...test LED flashes when CSW software is running normally GSM Not used GPS In normal operation the LED is on if a navigation fix is obtained If a fix is not found or is lost the LED stays off Photocell i...