Oasis VERSACOOLER II Instructions Download Page 1

OASIS

®

 VERSACOOLER

®

II MODELS 

 

 

SPLIT LEVEL INSTRUCTIONS 

 

A.

 

INSPECTION 
Inspect the water cooler, water fountain and cartons for evidence of rough handling and concealed damage.  Damage claims should be filed 
with the carrier. 

B.

 

TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE 
1.

 

NOTE:  The following states require a licensed plumber to install cooler; AG, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI. 
CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well.  State and local plumbing codes may prohibit use 
of saddle tapping valves for water line connection in some applications.  All connections must conform to applicable plumbing codes. 

2.

 

The  P8ACSL  is  composed  of  a  water  cooler  and  a  water  fountain.  The  water  cooler  contains  the  refrigeration  system  and  is  always 
mounted  on  the  right  side.  This  unit  can  be  configured  with  the  water  cooler  high  or  low.    Refer  to  proper  roughing  in  drawing  for 
location of plumbing and electrical service.  Filter units have additional instructions on a label inside fountain side access panel.  Read 
these before installing unit.  This drinking water cooler is designed to be operated at a water supply line pressure of up to 100 psi 
(690  kPa).    A  pressure  regulator  must  be  installed  in  front  of  the  unit’s  water  inlet  if  the  water  pressure  (including  any  possible 
pressure spikes) could exceed 100 psi (690 kPa). 

3.

 

FLUSH BUILDING WATER SUPPLY BEFORE INSTALLING UNIT. 

4.

 

Install wall hangers as shown on the desired roughing in drawing.  Wall hangers are shipped fastened to the backs of each unit. 

5.

 

To  configure  this  cooler  for  right  side  high  or  right  side  low  installation,  refer  to  details  below.    Bottom  screws  of  the 
appropriate  side  panel  may  be  temporarily  removed  to  install  patch  plate.    Assemble  drains  as  shown  below,  matching  the 
position of the gaskets to the contour of the cooler tops. 

6.

 

Mount the water cooler on the right hanger. 

7.

 

Mount  water  fountain  on  left  side  hanger  while  routing  “Water  In”  tube  through  access  hole  to  stop  valve  as  required.  Remove  cap 
from “Drain/Remote Cold Water” connection and insert “Water In” tube.  

8.

 

All  provided  waste  drain  parts  for  field  installation  are  packed  in  the  water  fountain.    Assemble  drain  per  appropriate 
roughing in drawing.  The short leg of the crossover piece will be on the water cooler side.  When unit has an internal waste 
trap,  it  should  be  wrapped  with  insulating  tape  to  prevent  sweating.    Use  of  1-3/4”  knockout  for  a  waste  line  is  not 
recommended because of potential conflict with ADA* toe space requirements.  Check with your local building code inspector 
for approval. 

9.

 

Install a shut off valve in water supply line.  An in-line strainer is furnished in “Water Supply” tube.  Connect “Water Supply” tube to 
shut off valve. This connection should not be a solder joint or flare connection to allow access to the strainer service.  To ease removal 
of the strainer, a sheet metal screw may be lightly threaded into the open end.   

10.

 

Rotate fan blade by hand to see that it is free of obstructions. 

11.

 

Check  available  power  supply  against  water  cooler  data  plate  to  assure  correct  electrical  service.    This  drinking  water  cooler  is 
intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL requirements.  Plug power 
supply  cord  into  wall  outlet.    The  rear  most  1-3/8  diameter  knockout  in  frame  bottom  is  for  an  externally  located  electrical  supply.  
Make sure knockout hole edge is smooth and free of any burrs.  Use of Heyco bushing #2184 in knocked out hole is recommended to 
prevent  damage  to  service  cord  and  to  close  up  excess  opening  around  cord.    Route  cord  so  it  does  not  interfere  with  ADA*  space 
requirements. 

12.

 

To fill cold water tank on water cooler, open water supply line shut-off and push any one of front push pads to allow water to flow to 
bubbler.  On  TM and  TT models, actuate solenoid by holding  one hand approximately 1” from infrared sensor  (under  front  edge of 
shelf).  Run water until stream is free of bubbles.  After approximately 30 seconds run time, solenoid valve will automatically shut off.  
To reactivate, move hand away for an instant and then again place it in front of sensor. 

13.

 

To Adjust Bubbler stream: 

All models are equipped with a cartridge regulator.  The standard push pad and electric eye models have a slot at back of underside 
of  shelf.    Insert  a  screwdriver  in  this  slot  to  adjust  regulator.    Turn  adjustment  clockwise  to  increase  stream  height.    To  access 
PGV8ACSL and PGVF8ACSL adjustment, remove the Bezel and Button from front of cooler. 

14.

 

To adjust beam range of sensor (TM and TT models only): 
a)

 

Shut off water.  Actuate sensor to relieve water pressure.  NOTE:  Unplug cooler or avoid touching fan blade and electrically live 
components when adjusting sensor. 

b)

 

Remove six screws holding top on.  Lift up front to access sensor. 

c)

 

To  adjust  sensing  distance,  use  a  mini-screwdriver  (2.5mm  flat  tip  or  smaller)  and 
rotate  adjustment  potentiometer  screw  on  side  of  sensor.    Turn  clockwise  to  sense 
objects further away.  This is represented by thicker end of curve on sensor label.  The 
screw  can  be  turned  a  maximum  of  ¾  turns.    Sensor  has  a  maximum  range  of 
approximately 14”, it is factory set at 4”. 

d)

 

NOTE: Do not turn adjustment as high as it can go.  If you do, sensor will lock on until you turn sensing distance back down. 

e)

 

There is an adjustable on-time delay if desired.  It is factory set for immediate response upon activation.  To adjust on-time delay, 
rotate blue knob on timer clockwise.  The maximum on-time delay is 1 second.  Water will shut off immediately once object is 
removed  from  under  shelf.    Maximum  on-time  is  30  seconds  should  someone  tamper  with  sensor.      NOTE:    Floors  with  a 
reflective finish, i.e., ceramic tile, may cause false actuation no matter what sensor adjustment is for distance.  Therefore, do not 
install unit in such an area or dull surface of floor so it will not reflect light. 

f)

 

Replace top, starting at back of unit, snug up screws, but do not overtighten.  

Adjustment 
potentiometer for 
sensing distance 

Reviews: