B_1RREC / POU_1RREC Series
Installation & Service Instructions
030099-499 RevOrig
pg 21 of 22
© Copyright 2014 OASIS Europe
o
Ensure all wires are connected to the CO2 electronic board
o
Ensure pump is running when button is pressed
o
Water within cooling system is frozen. Refer to the notes for “Water flows from the hot
system, and no water flows from cold system”
o
Ensure solenoid is working when button is pressed.
•
Erratic flow when CO2 button is pressed:
o
Adjust Flow regulator.
Accessing the Internal Chassis:
In order to carry out repairs to the refrigeration system, you may need to remove the side panel(s) from
the cabinet. Please follow the instructions given below to carry out this operation:
SAFETY INSTRUCTIONS
•
Isolate the water cooler from the water supply – this may be done by removing 19L bottle from
cooler
[Bottle version only]
or closing any shut-off valve fitted to the installation or temporarily
disconnecting the cooler from the water supply
[POU version only]
.
•
Disconnect the cooler from the power supply.
Remove Top from the Cooler:
•
Remove the two screws at the rear of the top, and lift off the lid assembly
Remove Side Panel
•
Remove the four screws as shown
•
Lower the panel vertically by about 20mm (3/4”) so that it clears the key slot, then lift the panel
away from the cooler