B_1RREC / POU_1RREC Series
Installation & Service Instructions
030099-499 RevOrig
pg 16 of 22
© Copyright 2014 OASIS Europe
Connecting POU cooler to water supply
All OASIS POU water coolers are supplied with a push-fit connector that should be used to connect
the cooler to the water supply. Oasis International recommends that these guidelines should be
followed when installing the cooler:
•
Use ¼” diameter tubing to connect the water supply to the water cooler. Although 6 mm tubing
will appear to fit, it is approximately 5% smaller in size. The use of 6mm tubing will result in a
leak.
•
A pressure regulator, such as a slow flow regulator, must be installed in front of the unit’s water
inlet if the water pressure (including any possible pressure spikes) could exceed 690 kPA (100
psig.). Failure to comply will void the warranty. The manufacturer accepts no liability for
damage caused by excessive water pressure.
TO PUT POU WATER COOLER INTO SERVICE
1.
This unit is suitable for indoor use in domestic, commercial & industrial locations. They should
not be sited in locations where they may be subjected to rain or snow.
2.
Carry the cooler in the upright position to the customer’s premises - use the handle at the rear of
the unit.
3.
Remove the shipping bag from the cooler.
4.
Carry out a general inspection of the cooler, ensuring that :
o
There are no marks or physical damage to the cooler.
o
That all accessories are present.
o
That all the wires and electrical connections are in place at the back of the cooler.
o
That the cooler is clean and dust free.
5.
Level the machine using the adjustable feet
6.
The water cooler should be located a minimum of 2" from the wall to assure adequate condenser
air circulation.
7.
Power cords fitted to the cooler must be tied securely to the back of the unit (base) using the cord
restrainer supplied, in such a way that it is not possible to remove the power cord from the
appliance by pulling on the flexible cord.
8.
Ensure that the appliance is positioned to give access to the plug after the unit is installed.
9.
Recommended ambient temperatures for correct operation of the unit are between 10ºC and 32ºC
10.
For safe operation, the unit should always be placed on a level surface.
11.
Cold water temperatures may be adjusted via a slotted screw on the body of the control (can be
accessed through wires on the condenser). Turning this screw in the clockwise direction will
make the water colder (and vice versa)
12.
The A-weighted sound pressure level of this appliance is below 70 dB
CAUTION: DO NOT INSTALL THE WATER COOLER IN AN AREA WHERE
WATER JETS MAY BE USED
13.
If filter(s) are to be added, follow filter manufacturer’s recommended instructions.
14.
Push a ¼” OD tube into the fitting to connect to cold water supply.