Replacing The Squeeze Tube
The first thing that you will need to do is open the App Menu
and go into Chemical Setup. When you are is the Setup menu
you will need to turn the Acid Dosing button to the Off position.
This will stop the peristaltic pump from operating while you are
replacing the Squeeze Tube.
Remove the tubing from the Intake and Output sides of the
Peristaltic Pump.
To replace the squeeze tube of the Peristaltic pump, you will
need to remove the head cap (green cover).
To remove, put your thumb under the lip at the bottom of the
head, gently but firmly lift the cover.
The head cover will come off
to expose the squeeze tube
and the head.
The pump head can be pulled out (the squeeze tube will come
with it) and a new squeeze tube can be wrapped around the
head, and the head re-installed onto the motor shaft.
Ensure that you apply some appropriate, silicon-based
lubricant onto the pump head and the squeeze tube.
Once the lubricant has been applied, the head cover can be
re-installed. Ensure that the squeeze tube is seated properly.
Re-attach the tubing running from the bottle and running to the
dosing manifold, making sure that both are clean and clear.
Once re-installed, ensure that you go back into the Chemical
Setup menu in the App and turn the Acid Dosing button back
to the On position and prime the dosing pump as per page 9 of
this manual.