background image

-  English  - 

10 

 

Storage/Over-wintering 

  Put the unit out of operation at water temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures 

are to be expected. 

  Drain and thoroughly clean the unit, check for damage. 

  Remove, clean, dry and store all filters in a frost-free environment. 

  Ensure that the storage place is inaccessible to children. 

  Cover the filter container such that the ingress of rain water is excluded. 

  Drain all hoses, pipes and connections as far as possible. 

 

Wear parts 

The UVC lamp, the quartz glass and the filters are wear parts and are excluded from the warranty. 

 

Disposal 

 

 

Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided. 
Disable the unit beforehand by cutting off the cables. 

 

Only dispose of the UVC lamp by using the return system provided for this purpose. 

 

Remedy of faults 

 

Malfunction

 

Cause

Remedy

The unit performance is not satisfactory 

Unit has been in operation only for a short time 

The complete biological cleaning effect is only 
achieved after several weeks 

Water extremely soiled 

Remove algae and leaves from the pond, 
change the water 

Excessive fish and animal population 

Guide value: approx. 2 ft (60 cm) fish length in 
265 gal (1 m³) pond water 

Foam filters soiled 

Clean filters 

Quartz glass tube soiled 

Remove UVC and clean quartz glass 

UVC lamp capacity exhausted 

Replace the lamp after approx. 8,000 operating 
hours 

UVC lamp display is not lit 

Power supply of Filtoclear-UVC not connected  

Connect UVC power plug 

UVC lamp defective 

Replace the UVC lamp 

Connection defective 

Check electrical connection 

UVC overheated 

UVC automatically switches on when cooled 
down 

No water outlet from the pond inlet 

Pump power supply not connected 

Connect pump power supply 

Pond inlet blocked  

Clean pond inlet 

Filter container/pump housing clogged 

Clean filter container/pump housing 

 

40370-09-14_GA_BioPress 1600_USA10   10

18.09.2014   11:19:25

Summary of Contents for BioPress 1600

Page 1: ...40370 09 14 BioPress 1600 Operating instructions Instrucciones de uso Notice d emploi 40370_GA_BioPress_1600_USA_A5_end_ 16 09 14 15 52 Seite 2...

Page 2: ...2 BPS0001 40370 09 14_GA_BioPress 1600_USA2 2 18 09 2014 11 19 21...

Page 3: ...3 A BPS0003 B BPS0017 C BPS0005 40370 09 14_GA_BioPress 1600_USA3 3 18 09 2014 11 19 21...

Page 4: ...4 D BPS0007 E BPS0009 40370 09 14_GA_BioPress 1600_USA4 4 18 09 2014 11 19 22...

Page 5: ...5 F BPS0014 40370 09 14_GA_BioPress 1600_USA5 5 18 09 2014 11 19 24...

Page 6: ...lead to death or severe injuries if the appropriate measures are not taken Important information for trouble free operation Intended use BioPress 1600 referred to in the following as unit may only be...

Page 7: ...stricted access to the cover to be able to carry out work on the unit Start up Attention Dangerous electrical voltage Possible consequences Death or severe injury Protective measures Electrical units...

Page 8: ...rs are mechani cally cleaned until the draining water is clear Switch off the filter pump Remove the dirt drain hose and correctly reconnect the hoses for normal operation Figure A Full cleaning E Dis...

Page 9: ...the O ring towards the front with a slight turning movement 4 Check the quartz glass and the O ring for damage and replace if necessary Clean the quartz glass outer face with a moist cloth Replacing t...

Page 10: ...lfunction Cause Remedy The unit performance is not satisfactory Unit has been in operation only for a short time The complete biological cleaning effect is only achieved after several weeks Water extr...

Page 11: ...muerte o graves lesiones si no se toman las me didas correspondientes Indicaci n importante para un funcionamiento sin fallos Uso conforme a lo prescrito BioPress 1600 en lo sucesivo el equipo solo pu...

Page 12: ...m Observe de que se pueda acceder a la tapa sin problemas para poder ejecutar los trabajos en el equipo Puesta en marcha Atenci n Tensi n el ctrica peligrosa Posibles consecuencias La muerte o lesione...

Page 13: ...exible de desag e de suciedades y conecte los tubos flexibles de forma correcta para el funcionamiento normal ilustraci n A Limpieza completa E Quite todos los tubos flexibles desenroscando las tuerca...

Page 14: ...ro hacia delante 4 Compruebe si el vidrio cuarzoso y el anillo en O est n da ados y sutit yalos si fuera necesario Limpie el vidrio cuarzoso por fuera con un pa o h medo Sustituci n de la l mpara UVC...

Page 15: ...l equipo funciona desde hace poco tiempo El pleno efecto limpiador biol gico se alcanza despu s de algunas semanas El agua est extremadamente sucia Elimine las algas y hojas del estanque Cambie el agu...

Page 16: ...i les mesures correspondantes ne sont pas prises Consigne importante pour un fonctionnement exempt de d rangement Utilisation conforme la finalit BioPress 1600 appel par la suite appareil doit tre uti...

Page 17: ...e afin de pouvoir effectuer des travaux sur l appareil Mise en service Attention Tension lectrique dangereuse Cons quences ventuelles mort ou blessures graves Mesures de s curit Appareils lectriques e...

Page 18: ...pompe Retirer le tuyau d coulement de la salet et raccorder correctement les tuyaux pour l exploitation normale figure A Nettoyage complet E Retirer tous les tuyaux en desserrant les contre crous 1 Ou...

Page 19: ...4 V rifier la pr sence ventuelle de d t riorations au niveau du verre quartz et du joint torique et le cas ch ant les remplacer Nettoyer l ext rieur du verre quartz avec un chiffon humide Remplacement...

Page 20: ...t L appareil n est en service que depuis peu de temps L effet de nettoyage biologique complet n est atteint qu apr s quelques semaines L eau est extr mement sale Retirer les algues et les feuilles du...

Page 21: ...maximum pres sure of 2 9 psi 0 2 bar Do not dispose of together with household waste Attention Read the operating in structions FR Protection contre le contact de pi ces dangereuses Prot g con tre les...

Page 22: ...22 BPS0013 40370 09 14_GA_BioPress 1600_USA22 22 18 09 2014 11 19 25...

Page 23: ...40370 09 14_GA_BioPress 1600_USA23 23 18 09 2014 11 19 26...

Page 24: ...OASE North America Inc www oase livingwater com 40370 09 14 40370 09 14_GA_BioPress 1600_USA24 24 18 09 2014 11 19 26...

Reviews: