background image

The tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is 

rated for the table. (See Grounding below)
Arrange the power cord and control cords so that they will not create a tripping hazard.
Be sure access to the plug is not blocked for disconnecting the table from power.

GROUNDING FOR 120 VOLT PRODUCTS:
This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug 

shown below. See Grounding Methods - US 120V Example. Make sure that the product is connected 

to an outlet having the same configuration as the plug. No adapter should be used with this product.

GROUNDING FOR 230 VOLT PRODUCTS:
This product is rated for less than 15 amperes and is for use on a circuit having a nominal rating 

of 230 volts and is factory-equipped with specific electric plug to permit connection to a proper 

circuit. Make sure that the product is connected to an outlet having the same configuration as the 

plug. No adapter should be used.

WARNING

1.  Improper connection of the equipment-grounding conductor can result in a risk of  electric 

shock. Check with a qualified electrician or service person if you are in doubt as to whether 

the product is properly grounded.

2.  Do not modify the plug provided with the product - if it will not fit the outlet; have a proper 

outlet installed by a qualified electrician.

Correct Implementation

Incorrect Implementation

Risk of Electric Shock - Connect this furnishing to a properly grounded outlet only.

DANGER

INSTALLATION

GROUNDING

Grounding Methods - US 120V Example

16

Summary of Contents for Icon

Page 1: ...USER MANUAL www OAKWORKS com 717 235 6807 Icon Talise Maia Legacy Britta Palas OAKWORKS Masters Collection Tables...

Page 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifica tions and the like documen...

Page 3: ...Control Operation Britta Palas Salon Top Tables 15 Installation Grounding 16 Directions for Use Moving the table 17 Key Lock Use 17 Removing Top Pad 18 Adjustable Breast Comfort ABC System Use Option...

Page 4: ...es that when the end user wishes to discard this product it must be sent to separate collection facilities for recovery and recycling U L 2601 1 C S A C 22 2 N O 601 1 IE C 60601 2 2001 09 C U S U S L...

Page 5: ...roducts are being used or where oxygen is being administered 7 Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufactur...

Page 6: ...8 Do not place foreign objects into the ABC System 9 Only use the ABC system as intended 10 For safety of your client use a cloth sheet between the ABC System and your client 11 Be certain that the t...

Page 7: ...ODEL OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMENT CONTAINS TECHNICAL INFORMATION PROPRIETARY TO OAKWORKS INC THE DISCLOSURE TO OTHERS OR USE OF THIS TECHNICAL INFORMATION IN ANY WAY WITHOUT...

Page 8: ...BC MODEL OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMENT CONTAINS TECHNICAL INFORMATION PROPRIETARY TO OAKWORKS INC THE DISCLOSURE TO OTHERS OR USE OF THIS TECHNICAL INFORMATION IN ANY WAY WIT...

Page 9: ...L x 24 D x 11 H Storage Load Capacity 75 lbs Warming Drawer Inside Area 19 D x 17 W x 3 H Warming Drawer Capacity 16L OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMENT CONTAINS TECHNICAL INFORMA...

Page 10: ...e height of the table and optional ABC PRODUCT DESCRIPTION 4 LEG TABLES ABC System UP ABC System DOWN Height DOWN Height UP FOOT CONTROL WITH ABC STANDARD FOOT CONTROL Height Up Height Down Memory 1 F...

Page 11: ...EG TABLES Height Down Height Up Backrest Down Footrest Down Footrest Up Backrest Up Height Down Backrest Down Footrest Down Height Up Footrest Up Backrest Up ABC Down ABC Up STANDARD FOOT CONTROL FOOT...

Page 12: ...H Warming Drawer Capacity 16L UPHOLSTERED TOP MODELS 1 Section Flat Top 1 Section Fuzion Flat Top 4 Section Salon Top 4 Section Fuzion Salon Top OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMEN...

Page 13: ...the height of the table and optional ABC PRODUCT DESCRIPTION 2 COLUMN TABLES ABC System UP ABC System DOWN Height DOWN Height UP FOOT CONTROL WITH ABC STANDARD FOOT CONTROL Height Up Height Down Memor...

Page 14: ...COLUMN TABLES Height Down Height Up Backrest Down Footrest Down Footrest Up Backrest Up Height Down Backrest Down Footrest Down Height Up Footrest Up Backrest Up ABC Down ABC Up STANDARD FOOT CONTROL...

Page 15: ...ered 20 5 34 5 52 88 cm Height with 4 foam 2 Powered 17 Trendelenburg Reverse Trendelenburg 2 Powered 0 80 Backrest Foot Control All powered motions 3 Powered 0 30 Thigh 0 19 Footrest Hand Control All...

Page 16: ...lbs 227 kg client and accessories Padding 4 10 cm or 6 15 cm AeroLux Foam OPTIONS ACCESSORIES 120V or 230V External Outlets 2nd Foot Control 2nd Hand Control All powered motions and Memory Positions B...

Page 17: ...he Trendelenburg height and optional ABC functions of the table Height Down Height Up Height Down Height Up ABC Down ABC Up STANDARD FOOT CONTROL FOOT CONTROL WITH ABC Head End Down Head End Up Head E...

Page 18: ...Tables offer trendelenburg height backrest footrest and optional ABC positioning with electronic ease Operate the foot and hand control as shown below to raise or lower the tren delenburg height back...

Page 19: ...ct is rated for less than 15 amperes and is for use on a circuit having a nominal rating of 230 volts and is factory equipped with specific electric plug to permit connection to a proper circuit Make...

Page 20: ...otions It should be used to prevent unauthorized use Remove the key when not in use and store out of reach of children The green light on the switch indicates the table is on Key Lock Use I Unlocks th...

Page 21: ...thumbs screws are on too tight a 3 16 bit can be used 2 Lift top pad off the platform IF THE TABLE HAS A HEATED TOP Unplug the table from the wall outlet and disconnect the wires circled from the cont...

Page 22: ...ble Sometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlyde...

Page 23: ...ontrols the lower half of the pad The Zone 1 con troller is on the right side of the table Zone 2 controller is on the left side of the table Press both buttons to turn on both zones and heat the enti...

Page 24: ...to the bracket until bullet catches are snapped into place To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under...

Page 25: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Page 26: ...the table Position Bluetooth Speaker with the magnetic attachment facing up Plug the cord into the side of the speaker and attach it to the bracket CONNECTING TO BLUETOOTH SPEAKER Turn Bluetooth Speak...

Page 27: ...edure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts of...

Page 28: ...s and all visible wiring Visually inspect components for obvious damage that could cause problems during operation Check all mechanical functions using the hand control Repeat using the foot control C...

Page 29: ...lspring Rd New Freedom PA 17349 USA Phone 717 235 6807 www oakworks com 16796025 MIXX4R35ASH611USXXXSAGEAGIDPCXXDXX Ser MIS563146 07 18 2017 Order 785461 Maia 4 Sect XX 4 R 3 5 A SH 6 11 US XXX AS Sha...

Page 30: ...kPa Storage Transport 20 29 C to 135 57 C 20 to 95 RH 98 to 105 kPa ELECTRICAL SPECIFICATIONS Designed for North America Europe Input Service 120V 60Hz 12 0 Amps 220 240V 50Hz 8 3 Amps Plug Type s Ty...

Page 31: ...applicable regulations and requirements of the local state environmental protection agency state health agency Centers for Disease Control CDC Occupational Safety and Health Administration OSHA U S F...

Page 32: ...rs NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection...

Reviews: