background image

Model / Modèle

51-38

51-57MR

51-39

51-58MR

http://www.owlee.com/technical-information.aspx

BUILDING CODE AND FIXED PIPING SUPPLY REQUIREMENTS:   When an appliance is connected to a fixed gas piping 
supply system, the installation must conform to local building codes, or in the absence of local building codes, to the National 
Fuel Gas Code, ANSI Z223.1/NFPA 54, International Fuel Gas Code, Natural Gas and Propane Installation Code, CSA 
B149.1, or Propane Storage and Handling Code, B149.2, as applicable.

The link below will take you to the Owners Manual and Operating Instructions in French where you can download a copy.
Sélectionnez le lien ci-dessous pour télécharger les instructions françaises.

A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR

FIRE PIT FOR PROPANE AND NATURAL GAS 

(Requires Conversion Kit)

CASUAL FIRESIDE

Tested & Certified to

 ANSI Z21.97-2014/CSA 2.41-2014

CGA 2.17-M91 (R2014)

APPLIANCE BTU RATING

32,000 Propane / 44,000 Natural Gas

DANGER

This gas appliance is designed as an “attended appliance”.  Adults must be present when the unit is 
operating/burning.  

DO NOT leave this unit operating/burning when unattended.

  If this product is left 

operating/burning unattended it may cause serious injury or property damage.

        DANGER

Report #0521GM001S

WARNING
Improper - installation, adjustment, alteration, service or maintenance of this gas appliance can cause 
injury or property damage.  Read the installation, operating and maintenance instructions thoroughly 
before installing or servicing this gas appliance.

WARNING
Do not store flammable liquids or use gasoline or other flammable vapor producing products in the 
vicinity of this or any other gas appliance.  An LP- Propane cylinder not connected for use shall not be 
stored within 60" of this fire pit or any other gas burning appliance.

WARNING:  FOR OUTDOOR USE ONLY

2.  Extinguish any open flame.

INSTALLER

  - Owner’s Manual must be left with the 

consumer for future reference.

CONSUMER

 –  Owner’s Manual must be saved for 

future reference.

3.  If odor continues, keep away from the appliance and immediately call your gas supplier or the 
fire department. 

CARBON MONOXIDE HAZARD

    
This gas appliance can produce carbon monoxide 
which is an odorless, colorless gas.

Using this gas appliance in an enclosed space can 
kill you.

Never use this gas appliance in an enclosed space 
such as a camper, tent, car, home or garage.

1.  Shut off the gas supply to the appliance.

If you smell a gas or a rotten egg odor immediately:

V4-100117A

Summary of Contents for CASUAL FIRESIDE 51-38

Page 1: ...ttended If this product is left operating burning unattended it may cause serious injury or property damage DANGER Report 0521GM001S WARNING Improper installation adjustment alteration service or maintenance of this gas appliance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this gas appliance WARNING Do n...

Page 2: ...AN CAUSE SERIOUS INJURY OR DEATH FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain when you install this Outdoor Fire Pit THERE MUS...

Page 3: ...may not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 12 to the gas type you intend to use Any gas type conversion should be performed by a qualified profess...

Page 4: ... the fire pit top surrounding the flame and should stay away to avoid burns and clothing or long hair ignition DO NOT continue using your FIRE PIT if you smell any unusual odors or have headaches nausea or dizziness G WARNING DO NOT throw trash paper plastics or any other flammable materials into your Fire Pit WARNING DO NOT leave in operation when unattended H DO NOT use this appliance if any par...

Page 5: ... gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is not in use 4 5 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal CONNECTING AN LP GAS CYLINDER PROPANE TANK TO THE FIRE PIT Page 5 B Minimum Clearance to Combustibles Page 2 IMPORTANT BEFORE PROCEEDING CAREFULLY READ ALL OF THE IMPORTA...

Page 6: ...ISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and cause a pop and launch outside of the fire pit which could cause damage or injury Caution should be exercised when heating up the fire pit with lava granules to normal opera...

Page 7: ...res Figure 3 Pour the second bag of media onto the burner support Taper from the top of the burner towards the width edge Figure 1 Rectangle Burner Support and Stainless Steel Burner Figure 2 Pour the first bag of the glass media into the burner support Page 7 GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT Carefully inspect the carton for shipping d...

Page 8: ...YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and may pop an...

Page 9: ... on Converting Your Fire Pit to a Different Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessi...

Page 10: ...ructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor fire pit burner found to be defective during this warranty period Regular maintenance must be exercised as set forth in the owner s manual For more information go to www owlee com Items Not Cover...

Page 11: ...ied professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water Push in the manual gas control knob slightly and turn clockwis...

Page 12: ...ched to the orifice holder Figure 1 and unscrew the orifice holder from the burner pipe Figures 1 and 2 50 3 Remove the orifice from the holder Figure 2 and replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that the air intake holes are closed Figure 2 For P...

Page 13: ...XÉRIEUR MAGNIFIQUE ET SANS DANGER POUR LE GAZ PROPANE ET NATUREL Kit de conversion Nécessite Cet appareil est conçu en tant qu appareil à surveiller Des adultes doivent être présents quand l appareil fonctionne NE PAS le laisser brûler lorsqu il n est pas surveillé Si ce produit est laissé en train de brûler sans surveillance il peut entraîner des dommages matériels ou des blessures graves DANGER ...

Page 14: ...ON OU L UTILISATION DE VOTRE FEU EXTÉRIEUR PIT PEUT CAUSER DES BLESSURES GRAVES OU LA MORT DE FEU BURNS EXPLOSIONS OU AU MONOXYDE DE CARBONE INTOXICATION Parois 60 1 5 m du centre de l unité Figure 1 Plafond 60 1 5 m de haut de l unité au plafond ou faux Revêtement de sol 0 Peut être installé sur le pont la dalle le plancher etc Les dimensions indiquées dans la figure 1 sont MINIMUM DÉGAGEMENTS à ...

Page 15: ...Z EST INFÉRIEURE AU MINIMUM EXIGÉ OU DÉPASSE LE MAXIMUM E POUR LE GAZ NATUREL La pression minimale d admission du gaz pour les besoins de l ajustement de l entrée est de 88 9 mm 3 5 pouces de colonne d eau WC Water Column et la pression maximale d admission est de 266 7 mm 10 5 pouces WC POUR LE PROPANE La pression minimale d admission du gaz pour les besoins de l ajustement de l entrée est de 203...

Page 16: ...toyer la roche de lave ou en verre morceaux avec de l eau et sécher soigneusement avant d allumer Retirez toutes les toiles d araignée à l intérieur de l unité Effectuez périodiquement un contrôle visuel de la flamme du brûleur pour vous assurer qu il n a pas beaucoup changé en hauteur ou la coloration depuis le dernier être utilisé Toute modification significative de la hauteur de la flamme ou de...

Page 17: ...un garage ou autre espace fermé 6 Le cylindre de gaz propane doit être debout sur la base inférieure du cylindre conçu pour le retrait de vapeur appropriée LA BOUTEILLE LP GAS Réservoir de propane INFORMATION 1 2 Le cylindre s de gaz propane à utiliser doit être construit et marqué en conformité avec le Département des États Unis Transport D Ö T Spécifications pour GPL Cylindres ou la norme pour l...

Page 18: ...e rechange en cuivre nº 6 Connecteur de bouteille de propane nº 7 Orifice nº 8 Kit de conversion de gaz propane en gaz naturel nº 9 Kit de conversion de gaz naturel en gaz propane Approved Media nº 10 Kit de rocs en céramique avec granules de lave nº 11Kit de morceaux de verre érodés taille nº 3 9 12 mm 3 8 po nº 12 Kit de bûches en céramique avec granules de lave nº 13 Granules de lave 9 mm 3 8 p...

Page 19: ...er la disposition comme indiqué pour assurer le bon fonctionnement de votre feu PIT SI VOUS nécessité de repositionner TOUT MATÉRIEL POUR MAINTENIR l aménagement utiliser la chaleur GANTS résistants ou laisser le matériel suffisamment de temps pour COOL avant l utilisation GEM MIROIR ET TOMBA VERRE PLACEMENT DANS LES MEDIAS A Inspecter le carton avec soin pour s assurer qu il n a pas été endommagé...

Page 20: ...ENIR LA DISPOSITION TELLE QU ILLUSTRÉE AFIN D ASSURER LE BON FONCTIONNEMENT DU FOYER SI UN MATÉRIAU DOIT ÊTRE REPOSITIONNÉ POUR MAINTENIR UN ARRANGEMENT ADÉQUAT EMPLOYER DES GANTS RÉSISTANT À LA CHALEUR OU LAISSER LE MATÉRIAU EFROIDIR AVANT DE LE MANIPULER Remarque Granulés de lave utilisés dans un puits du feu lorsque chauffés à des températures normales de fonctionnement peuvent provoquer des ga...

Page 21: ...et l orifice Insérez un petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Util...

Page 22: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Page 23: ...nter une réparation peut entraîner un incendie ou une explosion NE PAS EMPLOYER cet appareil si une partie ou pièce s est trouvée sous l eau Appeler immédiatement un technicien professionnel et qualifié pour inspecter le foyer et remplacer le cas échéant des pièces du système de contrôle et de commande du gaz qui se sont trouvées sous l eau INSTRUCTIONS D ALLUMAGE STOP LIRE LES MESURES DE SÉCURITÉ...

Page 24: ...ler le manchon de l obturateur d air de telle sorte que les orifices d admission d air sont fermées Figure 2 Pour le gaz propane retirez l obturateur d air de telle sorte que les orifices d admission d air sont ouverts Figure 1 Après que l appareil est assemblé à l emploi il est besoin d un contrôle de fuite test sur toutes les connexions sont avant de placer l unité en fonctionnement 5 IL EST NÉC...

Reviews: