Fiber Optic Intrusion Detection System
NS-200S User Manual
Nxtar Fiber Optic Security Co.,Ltd.
Page 1: ...Fiber Optic Intrusion Detection System NS 200S User Manual Nxtar Fiber Optic Security Co Ltd Fiber Optic Intrusion Detection System NS 200S User Manual ...
Page 2: ...D ON open open open open TAMPER1 open closed open open INTRUDER1 closed open open open TAMPER2 open open open closed INTRUDER2 open open closed open Bottom View Left Side View left Relay Dry Contact Integration with CCTV search lights siren and etc BEEP OFF Authorized access control flexibility with software use 可暫時停止發送警報 Laser Output Input GND Rx Tx NC Leading Fiber MINI USB Connection port AC po...
Page 3: ...e 4 BEEP OFF Disable the alarm manually 5 INTRUDER LED When the LED blinks in red it indicates the pre warning When the LED is lit is red it indicates detection of intrusion 6 TAMPER LED When the LED is lit in green it indicates all detection zones operates normally When the LED is lit in red it indicates the tamper of optical path requiring maintenance 7 LED Displayer User can set up parameter an...
Page 4: ...tic Security Co Ltd Option 3 4 CH1 CH2 SENSITIVITY Option 2 SIGNAL MONITOR Option 1 ALARM MONITOR 3 System Menu Flow Chart Launch Screen Option 5 MAINTENANCE Option 6 OTHER Press UP DOWN to select and ENTER to enter a function Function Menu Press Function back to system menu ...
Page 5: ...he intruder finishes climbing over the fence detection zone COUNT It refers to within preset Period how many times that signals go beyond the threshold The system issues warning only when above three parameters meet the setting value Press UP DOWN to Option 4 主功能目錄 Press UP DOWN to Option 3 Press Select Enter to adjust CH1 Sensitivity Press Select Enter to set up other parameters Press Select Ente...
Page 6: ...Press Select Enter 鍵 Alarming Situation Normal situation in monitoring screen Press Select Enter CH1 PERIOD CH 1 LEVEL CH1 real time signal CH1 COUNT CH2 PERIOD CH2 LEVEL CH2 real time signal CH 2 COUNT CH1 real time counts CH2 real time counts Blinking refers intrusion The accumulated counts before pressing BEEP OFF It indicates CH2 is secure ...
Page 7: ...nter 鍵 Press Select Enter Press Select Enter 鍵 CH1 indicates LF failure and requires maintenance CH2 functions normally Sensing Fiber Failure Sensing Fiber and Leading Fiber failures It indicates the performance of the optical path When Optical path is decaying check on the glitch is required Press UP DOWN to adjust Level Press UP DOWN to adjust Count Press UP DOWN to adjust Level Press UP DOWN to...
Page 8: ...st the sound volume B_LIGHT Adjust the brightness of the LCD display OTHER Descriptions Press Select Enter 鍵 Press Select Enter 鍵 Press Select Enter 鍵 Press Select Enter 鍵 Press UP DOWN to adjust Press UP DOWN to adjust Press UP DOWN to adjust The parameter setting is recorded in second item CH1 three parameters setting value CH2 three parameters setting value Sound Volume ...
Page 9: ...ect exposure of the eye to the connectors 3 When TAMPER LED is lit it means the loss of a given detection zone is too high In this case users can do some simple cleaning on the SC connectors 4 Before cleaning SC connectors switch off the power first Avoid the direct eye exposure to the connectors 5 Connectors cleaning include laser output and input receivers 6 If necessary SJB and TJB connectors n...