NXP Semiconductors
UM10276_1
TED-Kit 2 User Manual
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2010. All rights reserved.
User manual
Rev. 1.29 — 20 August 2010
49 of 79
6.8 RKE applet window
To open this window, the appropriate tree node of the desired transponder family below
the Immobilizer/RKE or Immobilizer/RKE/PKE tree node of the applet view has to be
double-clicked.
The window itself consists of two sections. The upper section defines the infrastructure of
the applet by means of what base stations and what transponder family is being used.
The RKE tab of the lower section consists of the RKE application.
Infrastructure
Shows the currently configured infrastructure used by the RKE applet. The LF-
I
I
m
m
m
m
o
o
-
-
L
L
i
i
n
n
k
k
base station is needed for the tag resynchronization. The UHF
R
R
K
K
E
E
/
/
P
P
K
K
E
E
-
-
L
L
i
i
n
n
k
k
base station
is needed for the one-way RKE application itself. The
T
T
a
a
g
g
is the transponder family be-
ing used.
RKE Application
Shows all necessary controls to run the RKE application. The controls for the application
are:
S
S
t
t
a
a
r
r
t
t
– starts the RKE application.
S
S
t
t
o
o
p
p
– stops the RKE application.
R
R
e
e
s
s
y
y
n
n
c
c
– writes a new SYNC value into the tag. The new SYNC value can be given ei-
ther manually or by a random generator. In both cases the new value will be displayed.
R
R
e
e
s
s
y
y
n
n
c
c
s
s
t
t
a
a
t
t
u
u
s
s
:
C
C
h
h
a
a
n
n
g
g
e
e
d
d
- the new SYNC value has been changed successfully to the new value.
n
n
o
o
t
t
c
c
h
h
a
a
n
n
g
g
e
e
d
d
-
-
the SYNC value hasn’t been changed. Select a new Manual value or
choose Challenge to get a new value.
E
E
r
r
r
r
o
o
r
r
-
-
An error occurred during synchronization. Check the Tag type or the position and
distance to the antenna.
RKE settings
To set a new SYNC value to be able to run a RKE application a valid Remote Secret Key
and the SYNC value itself has to be given. The source of the SYNC value can be chosen
manually or by a random generator.
6.9 PKE applet window
To open this window, the appropriate tree node of the desired transponder family below
the Immobilizer/RKE/PKE tree node of the applet view has to be double-clicked.
The window itself consists of two sections. The upper section defines the infrastructure of
the applet by means of what base stations and what transponder family is being used.
The PKE tab of the lower section consists of the PKE applications.
Infrastructure
Shows the currently configured infrastructure used by the PKE applet. The LF-
I
I
m
m
m
m
o
o
-
-
L
L
i
i
n
n
k
k
base station is needed as uplink channel. The UHF
R
R
K
K
E
E
/
/
P
P
K
K
E
E
-
-
L
L
i
i
n
n
k
k
base station is needed
as downlink channel. The Tag window allows choosing the Transponder family.