Chapter 10
Power Management Controller (PMC)
10.1 Introduction
NOTE
For the chip-specific implementation details of this module's
instances, see the chip configuration information.
The power management controller (PMC) contains the internal voltage regulator, power
on reset (POR), and low voltage detect system (LVD).
See
AN4503: Power Management for Kinetis MCUs
for further details on using the
PMC.
10.2 Features
A list of included PMC features can be found here.
• Internal voltage regulator
• Active POR providing brown-out detect
• Low-voltage detect supporting two low-voltage trip points with four warning levels
per trip point
10.3 Low-voltage detect (LVD) system
This device includes a system to guard against low-voltage conditions. This protects
memory contents and controls MCU system states during supply voltage variations.
The system is comprised of a power-on reset (POR) circuit and a LVD circuit with a
user-selectable trip voltage: high (V
LVDH
) or low (V
LVDL
). The trip voltage is selected by
LVDSC1[LVDV]. The LVD is disabled upon entering VLPx, LLS, and VLLSx modes.
MKW01Z128 MCU Reference Manual, Rev. 3, 04/2016
Freescale Semiconductor, Inc.
195
Summary of Contents for MKW01Z128
Page 7: ...MKW01xxRM Reference Manual Rev 3 04 2016 viii Freescale Semiconductor Inc...
Page 11: ...MKW01xxRM Reference Manual Rev 3 04 2016 xii Freescale Semiconductor Inc...
Page 133: ...MKW01Z128 MCU Reference Manual Rev 3 04 2016 2 Freescale Semiconductor Inc...
Page 233: ...Module clocks MKW01Z128 MCU Reference Manual Rev 3 04 2016 102 Freescale Semiconductor Inc...
Page 513: ...Interrupts MKW01Z128 MCU Reference Manual Rev 3 04 2016 382 Freescale Semiconductor Inc...
Page 633: ...CMP Trigger Mode MKW01Z128 MCU Reference Manual Rev 3 04 2016 502 Freescale Semiconductor Inc...