Table 37-8. Compare modes (continued)
SC2[ACFGT]
SC2[ACREN]
CV1 relative
to CV2
Function
Compare mode description
1
1
Greater than
Outside range, inclusive
Compare true if the result is greater than or
equal to CV1
Or the result is less than or
equal to CV2.
With SC2[ACREN] =1, and if the value of CV1 is less than or equal to the value of CV2,
then setting SC2[ACFGT] will select a trigger-if-inside-compare-range inclusive-of-
endpoints function. Clearing SC2[ACFGT] will select a trigger-if-outside-compare-
range, not-inclusive-of-endpoints function.
If CV1 is greater than CV2, setting SC2[ACFGT] will select a trigger-if-outside-
compare-range, inclusive-of-endpoints function. Clearing SC2[ACFGT] will select a
trigger-if-inside-compare-range, not-inclusive-of-endpoints function.
If the condition selected evaluates true, SC1n[COCO] is set.
Upon completion of a conversion while the compare function is enabled, if the compare
condition is not true, SC1n[COCO] is not set and the conversion result data will not be
transferred to the result register, Rn. If the hardware averaging function is enabled, the
compare function compares the averaged result to the compare values. The same compare
function definitions apply. An ADC interrupt is generated when SC1n[COCO] is set and
the respective ADC interrupt is enabled, that is, SC1n[AIEN]=1.
Note
The compare function can monitor the voltage on a channel
while the MCU is in Wait or Normal Stop mode. The ADC
interrupt wakes the MCU when the compare condition is met.
37.5.6 Calibration function
The ADC is equipped with a calibration mechanism to provide high accuracy as specified
in the data sheet. It is mandatory to calibrate the ADC after power up or reset. Not
doing this can result in ADC conversion results with lower than specified accuracy.
In order to calibrate the ADC correctly, the following has to be done:
• On startup, wait until the reference voltage (VREFH) has stabilized.
• ADC has to be recalibrated after each system reset.
• Calibrate only one ADC instance at a time. So, when calibrating instance ADC0, the
instances ADC1, ADC2, etc. are required to be idle.
• Set ADCK (ADC clock) to half the maximum specified frequency.
Functional description
Kinetis KE1xF Sub-Family Reference Manual, Rev. 4, 06/2019
856
NXP Semiconductors
Summary of Contents for KE1xF Series
Page 2: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 2 NXP Semiconductors...
Page 138: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 138 NXP Semiconductors...
Page 360: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 360 NXP Semiconductors...
Page 490: ...Interrupts Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 490 NXP Semiconductors...
Page 562: ...Boot Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 562 NXP Semiconductors...
Page 706: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 706 NXP Semiconductors...
Page 736: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 736 NXP Semiconductors...
Page 866: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 866 NXP Semiconductors...
Page 1164: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1164 NXP Semiconductors...
Page 1178: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1178 NXP Semiconductors...
Page 1380: ...Usage Guide Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1380 NXP Semiconductors...
Page 1472: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1472 NXP Semiconductors...
Page 1482: ...Kinetis KE1xF Sub Family Reference Manual Rev 4 06 2019 1482 NXP Semiconductors...