Configuring the Hardware
BATT-14AAAPACKUG Rev. 1.0
Freescale Semiconductor, Inc.
9
5
Configuring the Hardware
5.1
Basic Configurations
The BATT-14AAAPACK is configured by default for an MC33771 and LOAD current sense.
To use the battery pack with the MC33772, position the jumper J4 between pins 1 and 2. This routes CT6 directly to VBAT.
To measure the M LOAD current through the 0.1 ohm sense resistor, position the jumper J7 between pins 2 and 3.
Note:
For the pack to be function, jumpers must be positioned on J4 and J7, and the fuse F1 must be in
place. Otherwise the battery stack is an open circuit.
Figure 5. BATT-14AAAPACK Configurations
Figure 6. BATT-14AAAPACK Connection to KIT33771TPLEVB
F1
J4
J7