ARCTIC STAR OPERATING MANUAL
NW Explorations | 31
The ‘Power’ breaker switches provide power to each engine to allow them to run. When the
breaker is switched on, the low-oil pressure alarm will sound until the engine is started and the
oil pressure rises to normal operating level and the alarm will stop
The ‘Vent’ breaker switches turn on the engine room fans. Use these fans when you are
underway to blow fresh air into the engine room.
6.4.1
Starting Procedure
1.
Be sure the engine throttle controls are at idle
2.
Switch the ‘Stop’ breaker switch to the ‘On’
position
3.
Switch both the port and starboard engine ‘Power’ breaker switch to the ‘On’ position
4.
Wait until the pre-heat lights go out.
5.
Press the port engine start button until the engine starts
6.
Press the starboard engine start button until the engine starts
7.
Turn both engine room vent fans on
8.
Check for seawater flow out of the exhaust ports at the stern of the boat
9.
Run the engine at idle or low RPM until the water temperature reaches 140°F; this can
be done as you untie the boat and maneuver out of the harbor at idle speed.
6.4.2
Stopping Procedure
1.
Let the engines run in idle for 5 minutes to cool down the engine; this can be done as
you idle into your destination to anchor or dock.
2.
Press the ‘Stopping’ button for each engine. The low
-oil pressure alarm will sound as the
oil pressure drops below the normal operating level.
3.
Turn the breaker switch of both engines to the ‘Off’ position.
4.
You may run the fans for several minutes to cool the engine room. These fans are pow-
ered from the 12-volt DC house bank and will deplete the batteries if left on too long.
6.5
Bow Thruster
The Side-Power bow thruster joystick control is to the right of the engine
controls. To operate, press ON and ON simultaneously. Test the thruster
with a quick push of the joystick in both directions. The bow will be moved
in the same direction that you move the joystick; push
the joystick to the starboard and the bow will move to
the starboard. This thruster unit will turn off
automatically if not used for three minutes or, if over
used and electric thermal shut off switch will trip. If this
occurs, you will need to let the unit cool down. If the
thruster will not turn on, check the breaker in the
forward stateroom, it is located below the bunk behind
the louvered doors. The breaker switch is a big red
button which is a pull-on, push-off. Be sure the
button is pulled out.
The bow thruster circuit breaker is in the
forward stateroom in the cabinet under the
bunk. The normal ‘On’ position is pulled out.