StubEQ

TM

Receiver Hub Installation Manual

Models NV-442, NV-842, NV-1642 and NV-3242

The StubEQ

TM

Receiver Hub is an active (amplified)

hub that allows the transmission of real-time mono-
chrome  or  color  video  for  distances  up  to  1,500ft
(460m),  (2,000ft  (600m)  if  the  transmitter  is  a 
NV-653T).  using  Category-2  or  better  Unshielded
Twisted-Pair (UTP) wire. The receiver hub continuously
and automatically compensates for cable attenuation,
and  ground-loops,  independent  of  the  video  signal
image. The 1U high hub is equipped with multi-stage
transient protection.

Wire Type

The StubEQ

TM

UTP Receiver Hub operates best with

Category-rated Unshielded twisted-pair (UTP) wire. It
may also be used with Category-rated foiled twisted-
pair (FTP) wire, or with multi-pair wire with an overall
shield (6 or more pairs). Wire gauges of 24 to 16 AWG
(0,5 to 1,3mm) are supported.

The video signal may co-exist in the same wire

bundle as other video, telephone, data, control signals,
or low-voltage power. It is also OK to run NVT signals
near electromagnetic fields (in accordance with Na-
tional Electrical Code, and other local safety require-
ments.

Do NOT use shielded twisted-pair wire unless it is

Category rated. Multi-pair wire with an overall shield
(6 or more pairs) is OK.

Do NOT use un-twisted wire.

Due to near-end crosstalk, do not send a transmit and
a receive signal in the same wire bundle. Exception:
Up to 1,000ft (300m); or 1,500ft (460m) Category 5
or better.

Up-the-Coax Pan/Tilt/Zoom telemetry signals are

NOT  supported.  Use  a  second  wire-pair  for 
RS-422 or RS-485 signals instead.

NVT recommends the use of factory-crimped RJ45

patch  cables  rather  than  unreliable  field-crimped
RJ45s to connect between the NVT device and an ad-
jacent female RJ45 jack.

Wire Distance

It is recommended that the wire distance be measured

to ensure that it does not exceed 1,500ft (460m), 2,000ft
(600m) if the transmitter is a NV-653T).

Recommended Wire Distance

:

All measured distances include any coax in the path.

Wire resistance may be measured with an ohm-meter
by shorting the two conductors together at the far end,
and measuring the loop-resistance out and back.

Loop Resistance per 1,000ft (300m)

24 AWG   (0,53 mm)         =           52 ohms
23 AWG   (0,57 mm)         =           42 ohms
22 AWG   (0,64 mm)         =           33 ohms
20 AWG   (0,81 mm)         =           21 ohms
19 AWG   (0,91 mm)         =           16 ohms
18 AWG   (1,02 mm)         =           13 ohms

Wire in underground conduit or wet locations must be

polyethylene-jacketed, gel-filled. Wire in plenum environ-
ments must be plenum-rated, per local codes.

Connecting the Camera End

Use any NVT passive transceiver, (such as the NV-214A-M)
or qualified OEM camera with built-in UTP output, or the
NV-653T Active Transmitter.  Install per the instructions
that come with the transmitting device.

Connecting the Monitor End

The  StubEQ

TM

Receiver  Hub  has  RJ45  jack  input 

connections  for  the  video  signals,  with  four  signals
grouped onto each RJ45 jack.

1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings.
8) Install in accordance with the manufacturer’s instructions.
9) Do not install near any heat sources such as radiators,

heat registers, stoves or other apparatus (including DVRs)

that produce heat.
10)  Do not defeat the safety purpose of the polarized or

grounding-type plug. A polarized plug has two blades with

one wider than the other. A grounding type plug has two

blades and a third grounding prong. The wider blade or the

third prong are provided for your safety. If the provided plug

does not fit into your outlet, consult an electrician for replace-

ment of the obsolete outlet.
11)  Protect the power cord from being walked on or pinched

particularly at plugs, convenience receptacles, and the point

where they exit from the apparatus.
12)    Only  use  attachments/accessories  specified  by  the 

manufacturer.
13)  Use only with cart, stand, tripod, bracket, or table spec-

ified by the manufacturer, or sold with the apparatus. When

a cart is used, use caution when moving the cart/apparatus

combination to avoid injury from tipover.
14) Unplug this apparatus during lightning storms or when

unused for long periods of time.
15) Refer all servicing to qualified service personnel. Servic-

ing is required when the apparatus has been damaged in any

way, such as a power supply cord or plug is damaged, liquid

has been spilled, or objects have fallen into the apparatus,

the apparatus has been exposed to rain or moisture, does

not operate normally, or has been dropped.

This installation should be made by a qualified

service person and should conform to all local codes.

WARNING - Do not install the unit in an environ-

ment where the operating ambient temperature exceeds

120° F (50° C). The ventilation should not be impeded by

covering the ventilation openings with items, such as

newspapers, table-cloths, curtains, etc. No naked flame

sources, such as lighted candles should be placed on

the apparatus.

WARNING  -  Do  not  interconnect  multiple 

outputs.

  WARNING - The apparatus shall not be exposed 

to dripping or splashing and no objects filled with liquids,

such as vases, shall be placed on the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

Camera

Monitor

NV-214A-M

CCTV Application 

Figure 1

UTP up to 1,500ft (460m)

Category-rated UTP

Stub

4-pair

Category-rated UTP

Monitor

NV-216A-PV

Power Supply Cable Integrator Hub

PVD Application 

Figure 2

EQ  Receiver

TM

StubEQ  Receiver

TM

Camera

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

DO NOT REMOVE COVER OR BACK.  NO USER

SERVICEABLE PARTS INSIDE.  REFER SERVICING

TO QUALIFIED SERVICE PERSONNEL.

WARNING: TO REDUCE THE RISK OF ELECTRI-
CAL SHOCK, DO NOT EXPOSE THIS APPARATUS
TO RAIN OR MOISTURE.

WARNING - Use only a Certified power cord and 

plug (coupler / mains) assemblies for location installed.

WARNING  -  Power  cord  is  regarded  as  main 

disconnect.

WARNING - The appliance coupler (power 

cord/mains) shall remain readily operable.

WARNING  -  For  safety,  never  put  NVT  signals  in 

the same conduit as high-voltage wiring.

WARNING - Do not restrict airflow around any 

active powered NVT products.

Cat 5  Wire Distance

Cat 5  Wire Distance

235

315

400

475

550

630

700

780

3 MHz

4 MHz

5 MHz

6 MHz

9 MHz

8 MHz

7 MHz

10 MHz

1

0

0

ft

C

a

m

e

ra

 L

in

e

o

f R

e

so

lu

tio

n

F

re

q

u

e

n

c

y

3

0

0

ft

1

,0

0

0

ft

1

 m

ile

3

,0

0

0

ft

1

0

,0

0

0

ft

3

0

m

1

0

0

m

3

0

0

m

1

,6

km

1

km

3

km

M

ax

P

as

s

iv

e

D

is

ta

n

c

e

M

ax

S

tu

b

E

Q

D

is

ta

n

c

e

M

a

x

D

ig

ita

lE

Q

D

is

ta

n

c

e

Reviews: