34
•
•
•
•
•
•
•
•
•
•
Interfaces
The systems support the following interfaces:
Data interfaces - InfiniBand
10/100/1000Mb Ethernet management interface (RJ45)*
USB port (uUSB connector)
RS232 Console port (RJ45)*
I²C interface*
Reset button
Status and Port LEDs
*This interface is not found in externally managed systems.
In order to review the full configuration options matrix, refer to
Management Interfaces, PSUs and
Data Interfaces
The data interfaces use QSFP56 connectors. The full list of interfaces per system is provided
Speed and Switching Capabilities
Each QSFP56 port can be connected with QSFP56 cable or connector for 40/56/100/200 Gb/s. The
system offers Class 7 (5W) QSFP56 transceivers support.
Speed
InfiniBand speed is auto-adjusted by the InfiniBand protocol. Mellanox systems support QDR/FDR/
EDR/HDR InfiniBand.
FDR is an InfiniBand data rate, where each lane of a 4X port runs a bit rate of 14.0625Gb/s
with 64b/66b encoding, resulting in an effective bandwidth of 56.25Gb/s.
EDR is an InfiniBand data rate, where each lane of a 4X port runs a bit rate of 25Gb/s with
64b/66b encoding, resulting in an effective bandwidth of 100Gb/s.
HDR is an InfiniBand data rate, where each lane of a 4X port runs a bit rate of 50Gb/s with
64b/66b encoding, resulting in an effective bandwidth of 200Gb/s.
RS232 (Console)
The Console port labeled “
” is an RS232 serial port on the back side of the chassis that is
used for initial configuration and debugging. Upon first installation of the system, you need to
connect a PC to this interface and configure network parameters for remote connections. Refer
to
Configuring Network Attributes
to view the full procedure.
This interface is not found in externally managed systems.