UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X 0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E4
2022/05/13
RP
2
3
1
9
WXYZ
_DA
Rack
Power
SHEET
1 OF 3
SCALE:N/A
$
$
%
%
&
&
'
'
(
(
)
)
*
*
+
+
-
-
.
.
/
/
0
0
Advantage Series
Metered
Switched
(DEFAULT)
TOP
FEED = 0
BOTTOM FEED = 2
(DEFAULT)
3m [10']
= 0
(DEFAULT) BLACK = 0
RED = R
GREEN = G
MODEL IS SHOWN IN DEFAULT CONFIGURATION. FOR
OPTIONAL CONFIGURATIONS, USE ITEM IDENTIFIER
CODE IN PLACE OF EACH ASTERISK. ORDERABLE
BASED ON FORMAT: R
P
2
3
1
9
* * * *
DO NOT INCLUDE TRAILING ZEROS IN * * * * SUFFIX
OPTIONS LISTED ON THIS ROW ARE NON STANDARD,
CONTACT SALES FOR ADDITIONAL INFORMATION
R
P
2
3
1
9
0.5m [1.6'] = A
1.5m [4.9'] = B
2.5m [8.2'] = C
1.2m [4'] = G
1.8m [6'] = F
(DEFAULT)
L5-
3
0P
=0
BLUE = B
WHITE = W
YELLOW = Y
IDENTIFICATION TABLE
INPUT PLUG
CHASSIS COLOR
CORD OPTION
ORIEN
*
TATION
ORANGE = A
1m [3.2'] = 1
2m [6.6'] = 2
*
*
*
NOTES
:
NATIONAL, STATE
1.
INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
AND LOCAL CODES.
2.
3.
PRIMARY DIMENSIONS ARE IN MILLIMETERS. SECONDARY DIMENSIONS
ARE IN [INCHES]
UNIVERSAL MOUNTING BRACKET IS AN ALTERNATIVE MOUNTING
METHOD TO THE TOOLLESS MOUNT FOR 3RD PARTY ENCLOSURES.
BRACKET IS PROVIDED WITH THE UNIT.
4.
DETAILED INSTALLATION INSTRUCTIONS CAN BE FOUND IN THE QUICK
START GUIDE
5.
CONNECT EXTERNAL EARTH GROUND TO THE 10-32 SIZE THREADED NUT
6.
7.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
INPUT PLUG CONFIGURATION (SEE IDENTIFICATION TABLE) FOR DUAL-
RATED UNITS, NEMA PLUGS ARE NAM RATED ONLY AND CAPTIVE AUS/NZ
PLUGS ARE EMEA RATED ONLY
MAX OPERATING
ELEVATION, ABOVE MSL
HUMIDITY
(OPERATING/STORAGE)
METERING ACCURACY
5-90% RH / 5-95% RH;
NON-CONDENSING
VOLTAGE(V), CURRENT(A), APPARENT
POWER(kVA), REAL POWER(kW),
POWER FACTOR, ENERGY(kWh)
3000M(9840FT)
RoHS COMPLIANT
COMPLIANCE
SAFETY&ENVIRONMENTAL
METERING ATTRIBUTES
FEATURES
INPUT POWER CORD:
METERED COMPONENTS
REMOTE OUTLET SWITCHING
ENVIRONMENTAL CONDITIONS
OPERATING TEMPERATURE
STORAGE TEMPERATURE
INPUT PLUG:
RATED POWER:
INPUT PHASE:
BREAKER QTY & TYPE:
INPUT CURRENT:
INPUT VOLTAGE:
OUTLET QTY & TYPE:
ORIENTATION:
UNIT TYPE:
TECHNICAL SPECIFICATIONS
MONITORED
SWITCHED
VERTICAL,
0U
MID
(
1
8
)
5-20R
100-120
VAC
3
0A (
24
A DERATED)
(2) 20AMP,SINGLE-POLE
SINGLE-PHASE
2
.9
kVA
SEE NOTE 7
SEE IDENTIFICATION TABLE
+-1% TO ISO/ IEC 62052-21
INPUT(PHASE), CIRCUIT BREAKERS
YES
-5 TO 60 C (23 TO 140 F)
-20 TO 60 C (-4 TO 140 F)
FRONT VIEW
BOTTOM VIEW
1000
10 100
Reset
Senso
r
Port 2
Rack
Power
100
10
Senso
r
Port 1
[
DARK
GRAY]
INPUT CORD
LENGTH SEE
IDENTIFICATION
TABLE
LJB
Hanson
[LIGHT GRAY]
ECN/ECO
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/13
LRF
E2
LRF
2022/07/04
OUTLET 'S COLOR UPDATE : BLUE --
>DARK GRAY
ECN-2207-0153
__ __
E3
Le
o
2022/0
8
/04
CB LABEL UPDATE
ECN-2208-0175
2022/10/08
2022/10/08
2022/10/08
LRF
E4
ECN-2210-0226
REVISE METER ACCURACY AND ATTRIBUTES CONTENT