11 

 

5.1.3

 

T/R Source or Sink 

The “

TRMODE

x

” command is used to configure the mode of the T/R Source or Sink I/O line, where “

x

” 

is 

either 0 or 1.  
The T/R Source or Sink settings are defined as: 

 

0 = Source Mode. In Source Mode, the T/R Source or Sink line functions as an output. While in 
Source Mode, an auto-sense circuit controls the T/R switching. When the Xtender is in transmit 
mode, a logic 

high

 signal will be output on this line. Conversely, when the Xtender is in receive 

mode, a logic 

low

 signal will be output on this line. 

 

 1  =  Sink  Mode.  In  Sink  Mode,  the  T/R  Source  or  Sink  line  functions  as  an  input,  and  the  T/R 
switching  is  controlled  by  applying  a  logic 

high

  or  logic 

low

  to  this  line.  Applying  a  logic 

high

 

signal to this line enables transmit mode, while applying a logic 

low

 enables receive mode. 

 

Note: Factory default setting is 0 (Source Mode)

 

The “TRVOLT

x

” command is used to configure the 

input and output logic levels

, where “

x

” is either 0 or 

1. The T/R Logic Level settings are defined as: 

 

0 = 3.3 VDC Logic 

 

1 = 5 VDC Logic 

 

Note: Factory default setting is 0 (3.3 VDC Logic).

 

5.1.4

 

Unit Status Command 

The “STAT?” command is used to display the system status. Information displayed in the system status is 

defined as: 

 

Model and Firmware Version 

 

Serial Number 

 

Input Attenuator Value (n/a for this product model) 

 

Feedback Attenuator Value (n/a for this product model) 

 

Transmit Threshold Control Value 

 

Pre-amplifier Control Value (n/a for this product model) 

 

T/R Source or Sink Mode Value and Logic Level 

 
 

 

Summary of Contents for NUPOWER XTENDER 12B04A-D27

Page 1: ...ER XTENDER 12B04A D27 BIDIRECTIONAL L S BAND AMPLIFIER PART NUMBER NW BA 12B04A D27 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product...

Page 2: ...porated into the chassis Completely Characterized The NuPower Xtender family of solid state bidirectional amplifiers has been completely characterized over temperature voltage and frequency These high...

Page 3: ...in transmit mode The integrated low noise amplifier provides a minimum of 13 dB of gain in receive mode Based on the latest Gallium Nitride GaN technology NuPower s high efficiency and 6 9 in 3 form f...

Page 4: ...ansmit RF Gain 15 dB typ Nominal Input Drive Level 27 dBm Maximum Input Drive Level 30 dBm Receive RF Gain 13 dB min Receive Noise Figure 3 5 dB typ T R Mode Automatic Sensing or Manual T R Line T R S...

Page 5: ...ONS Figure 2 NuPower Xtender 12B04A D27 Mechanical Outline Table 3 NuPower Xtender 12B04A D27 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connect...

Page 6: ...ratures may require additional heat sinking to maintain a baseplate temperature below 60 C at 100 transmit duty cycle Figure 3 The NuPower PA Kit offers out of the box operation for the user The fan c...

Page 7: ...Directly connecting to an antenna specified for the frequency range 1 0 to 2 5 GHz Connecting to an inappropriate antenna may result in damage to the amplifier module Connecting to a proper antenna th...

Page 8: ...into 50 otherwise the amplifier could be damaged 4 1 INTERFACE CONNECTOR The NuPower Xtender features a 9 pin Micro D interface connector for control power and ground connections Table 4 NuPower Xten...

Page 9: ...r an output source or an input sink When the T R line is configured in source mode the Xtender transmit and receive switching occurs automatically based on the T R level setting and the transceiver s...

Page 10: ...always ignored After receiving and processing a command the NuPower Xtender sends a Carriage Return terminated string as a notification that the command was completed 5 1 SERIAL COMMANDS Serial comman...

Page 11: ...recommended to set a lower transmit threshold control value The STAT command can be used to display the current Transmit Threshold Control value The TRLVLxxxx command is used to change the setting of...

Page 12: ...s controlled by applying a logic high or logic low to this line Applying a logic high signal to this line enables transmit mode while applying a logic low enables receive mode Note Factory default set...

Page 13: ...disposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted mun...

Page 14: ...and Sales Phone 513 360 0800 Email product sales nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 7 1 GENE...

Reviews: