6.10.6.3 WDT Wake-up
If WDT clock source is selected to 10 kHz, system can be woken-up from Power-down mode
while WDT time-out interrupt signal is generated and WKEN (WDT_CTL[4]) bit enabled. In the
meanwhile, the WKF (WDT_CTL[5]) flag will set to 1 automatically, and user can check WKF
(WDT_CTL[5]) flag by software to recognize if the system has been woken-up by WDT time-out
interrupt or not.
TOUTSEL
Time-Out Interval Period
T
TIS
Reset Delay Period
T
RSTD
000
2
4
* T
WDT
1024 * T
WDT
001
2
6
* T
WDT
1024 * T
WDT
010
2
8
* T
WDT
1024 * T
WDT
011
2
10
* T
WDT
1024 * T
WDT
100
2
12
* T
WDT
1024 * T
WDT
101
2
14
* T
WDT
1024 * T
WDT
110
2
16
* T
WDT
1024 * T
WDT
111
2
18
* T
WDT
1024 * T
WDT
Table 6.10-1 Watchdog Timer Time-out Interval Period Selection
T
TIS
WDT reset
( low reset )
T
RSTD
T
RST
T
WDT
T
WDT
: Watchdog Clock Time Period
T
TIS
: Watchdog Time
- out Interval Period ( (2
4
~ 2
18
) * T
WDT
)
T
RSTD
: Watchdog Reset Delay Period - Fixed 1024 * T
WDT
delay period
T
RST
: Watchdog Reset Period ( 63 * T
WDT
)
IF = 1
RSTF = 1
(if RSTEN = 1)
IF
WDT_CLK
RSTF
Figure 6.10-3 Watchdog Timer Time-out Interval and Reset Period Timing