background image

 

 
 

TBP-6/0923

Blood Pressure Monitor

 

 

 

 
 
 
 
 

Instruction Manual

Please read all instructions carefully and retain for future use

 

Summary of Contents for TBP-6/0923

Page 1: ...TBP 6 0923 Blood Pressure Monitor Instruction Manual Please read all instructions carefully and retain for future use...

Page 2: ...g 4 About Blood Pressure 5 Prepara on 6 Setup your Device 7 Se ng of User Year Date and Time 8 Before Measurement Measurement 9 Using Memory 10 Care and Maintenance 11 Troubleshoo ng EMC Declara on 12...

Page 3: ...u have a medical issue Not for use by children pregnant women or pre eclamptic patients If you suffer from arrhythmia diabetes blood circulation problems or apoplexy only use this device under a physi...

Page 4: ...st be installed and used according to the electromagnetic information Do not use this device where flammable gases or liquids are present Never drop the device Technical description is contained in th...

Page 5: ...Instrumenta on An irregular heartbeat IHB rhythm is defined as a rhythm that is more than25 slower or 25 faster from the average rhythm detected while the device is measuring the systolic blood press...

Page 6: ...Socket Cuff Set Button Memory Button USB power supply port Systolic pressure User number Blood pressure classification IHB Pulse rate Heartbeat Low battery Diastolic pressure Unit Indicator Year Date...

Page 7: ...ine ba eries according to the and markings Figure 2 3 Snap the ba ery cover on ensure it clicks into place NOTE When the low ba ery symbol appears on screen turn o this device and follow the instruc o...

Page 8: ...o confirm and then flashing hour digits occur 5 Press MEM to increase one hour or press and hold MEM to increase hours Press SET to confirm and then flashing minute digits occur 6 Press MEM to increas...

Page 9: ...easurements are desired allow two minutes between uses to allow blood to flow through the arm normally This device is used to monitor blood pressure However it cannot treat or prevent high blood press...

Page 10: ...user icon and press START STOP to confirm the user and then the device turns o U Using Memory R Recall This device will store up to 90 measurements each for two users When more than 90 measurements a...

Page 11: ...n Adjust cu ensuring it is wrapped properly and repeat measurement Do not move or talk during measurement Ensure cu is level with heart L Lo Low ba ery Correc on Replace ba eries following instruc ons...

Page 12: ...3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Group 1 Class B Not applicable Not applicable This device uses RF energy only for its internal function Therefore its RF emissions are very low...

Page 13: ...of this equipment could result NOTE UT is the a c mains voltage prior to application of the test level Immunity Test Electrostatic discharge ESD IEC 61000 4 2 Power frequency 50Hz 60Hz magnetic field...

Page 14: ...harmful interference in a residen al installa on This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance to the Instruc ons may cause harmful...

Page 15: ...e Within 5 of reading 6 Automatic inflation by pump 7 Deflation Automatic rapid deflation 8 Pressure Detection Semiconductor pressure sensor 9 Memory 2 persons X 90 measurements each 10 Power Supply 3...

Page 16: ...charge will be applicable for such repair or replacement S SERVICE AND REPAIR If service is required for this product you should first contact Nuvomed Inc Customer Service at info nuvomed us or by ca...