INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Heat-A-Vent

®

Combination

MODEL: 9905-RO2

FOR BEST RESULTS

In a new construction site, install the housing (complete

with heater and ventilator) during rough-in construction of

the building. The grille should be installed when the finished

ceiling is in place.

Installation in an existing, finished building requires an

accessible area (attic or crawl space) above the planned

location. See “INSTALLATION IN EXISTING

CONSTRUCTION.”

Do not install closer than 12 inches to a vertical surface.

Do not install over tub or shower enclosure.

For installation in sloped ceilings up to 12/12 pitch.

Ductwork must point up.

UNIT DIMENSIONS

Refer to Figure 1

for housing’s dimensions.

NOTE: If there will be a finished second floor above,

the Model 9905 housing requires a minimum of 2" x 8"

joist construction for mounting.

WIRING AND DUCTWORK

1. Run the required wiring during rough-in stage of construction.

2. Total connected load: 1630 watts.

3. Plan to run 120vAC, 60 Hz wiring (with ground) on a

separate 20 Amp circuit from a power source, through

the provided wall switch, to the housing’s junction box.

See wiring diagram.

4. Use 4" round duct.

FIGURE 1

7

3

4

"

14"

9

3

4

"

IMPORTANT INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING THIS

HEATER.

To reduce the risk of fire, electric shock, or injury to persons, observe the

following:

1. Use this unit only in the manner intended by the manufacturer. If you

have questions, contact the manufacturer at the address or

telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from

being switched on accidentally. When the service disconnecting

means cannot be locked, securely fasten a prominent warning

device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,

including fire-rated construction codes and standards.

4. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

5. This heater is hot when in use. To avoid burns, do not let bare skin

touch hot surfaces. Keep combustible materials, such as furniture,

pillows, bedding, papers, clothes, etc. and curtains at least 3 feet

(0.9 m) from the front of the heater.

6. Extreme caution is necessary when any heater is used by or near

children or invalids and whenever the heater is left operating and

unattended.

7. Do not operate any heater after it malfunctions. Disconnect power at

service panel and have heater inspected by a reputable electrician

before reusing.

8. Do not use outdoors.

9. To disconnect heater, turn controls to off, and turn off power to heater

circuit at main disconnect panel (or operate internal disconnect

switch, if provided).

10. Do not insert or allow foreign objects to enter any ventilation or

exhaust opening, as this may cause an electric shock or fire, or

damage the heater.

11. To prevent a possible fire, do not block air intakes or exhaust in any

manner.

12. A heater has hot and arcing or sparking parts inside. Do not use it in

areas where gasoline, paint, or flammable vapors or liquids are used

or stored.

13. Use this heater only as described in this manual. Any other use not

recommended by the manufacturer may cause fire, electric shock, or

injury to persons.

14. Install heater at least 12 inches from floor or any adjacent wall.

15. To avoid electrical shock: Do not install unit in a tub or shower

enclosure or any location where it may come in contact with water.

Never place a switch where it can be reached from a tub or shower.

16. This product is designed for installation in ceilings up to a 12/12 pitch.

Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN

A WALL.

17. Do not connect heater to dimmer switch or speed control.

18. Ducted fans must always be vented to the outdoors.

19. Provide a separate 20 AMP circuit. Use 12 GA. power cable of type

which meets code.

20. This product must be grounded.

SAVE THESE INSTRUCTIONS

30042494B