NuTone 9417DNM Installation Instructions Manual Download Page 1

1

IMPORTANT SAFETY INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock service panel to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a quali-

fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.

5. When cutting or drilling into wall or ceiling, do not damage elec-

trical wiring and other hidden utilities.

6.

Do not 

install this unit over a tub or shower.

7.

Never 

place a switch where it can be reached from a tub or

shower.

8.

Do not

 operate unit with dimmer switch or speed control.

CAUTION

1. For general ventilating use only. 

Do not

 use to exhaust haz-

ardous or explosive materials and vapors.

2. This product is designed for installation in flat ceilings only.

DO NOT MOUNT THIS PRODUCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

4. Please read specification label on product for further informa-

tion and requirements.

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Bulb Heaters & Bulb Heater/Fans

MODELS: 9417DNM, 9420WHC, 9425WHC

PLAN THE  INSTALLATION

Choose the location for your heater. Refer to Warnings and Cau-
tions.

MODELS 9417DNM & 9425WHC ONLY – 

The unit will operate

most efficiently when located where the shortest possible duct run
and minimum number of elbows will be needed. Units are de-
signed for use with standard 4" round duct.
Note that two-bulb units can be fitted with one infrared bulb (for
heat) and one reflector bulb (for light). Dual or multi-controls can be
used for separate control of bulbs and/or exhaust fan. Purchase
controls separately.

Refer to FIGURE 1

Follow these basic steps when installing this unit:
1. Nail unit to joists.
2. Attach ductwork (Models 9417DNM & 9425WHC only).
3. Connect power cable.
4. Fasten grille to housing.

PREPARE THE  HEATER

1. Remove the unit from carton. Save carton for use as plaster

shield in rough-in installations.

Refer to FIGURE 2

2. Slide adjustable mounting brackets into bracket channels on

housing.

FIGURE 1

DAMPER/DUCT

CONNECTOR

POWER CABLE

HOUSING

CEILING

JOIST

CEILING MATERIAL

BULB(S)

GRILLE

MOUNTING

BRACKET

FIGURE 2

Summary of Contents for 9417DNM

Page 1: ...e unit with dimmer switch or speed control CAUTION 1 For general ventilating use only Do not use to exhaust haz ardous or explosive materials and vapors 2 This product is designed for installation in...

Page 2: ...om construction dust drywall spray paint etc by using the plaster shield Cut it from the carton and follow directions printed on it 2 Finish all ceiling work as necessary 3 Remove plaster shield and c...

Page 3: ...GRAY 120 VAC LINE IN GROUND BLACK BLACK LIGHT BLACK to BLACK GROUND HEAT RED DUAL CONTROL RED to RED WHITE to WHITE 120 VAC LINE IN GROUND LIGHT DUAL CONTROL 3 WHITE GRAY WIRES VENT HEAT BLACK to BLA...

Page 4: ...you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CON SEQUENTIAL...

Page 5: ...il avec un gradateur ou un variateur de vitesse ATTENTION 1 Cet appareil convient des fins de ventilation g n rale uniquement Ne l utilisez pas pour l vacuation de mati res ou de vapeurs dangereuses o...

Page 6: ...r ceptacles d ampoule et les fils contre la poussi re de construction le pl tre ou la peinture l aide de l cran protecteur inclus D coupez celui ci dans la bo te de carton et suivez les instructions...

Page 7: ...IR et BLEU ROUGE au ROUGE et JAUNE TERRE ROUGE BLANC au BLANC NOIR ENTR E 120 VCA TERRE VENT COMMANDE DOUBLE 3 FILS BLANCS GRIS CHALEUR et LUMI RE NOIR au BLEU ROUGE au ROUGE NOIR et JAUNE TERRE ROUGE...

Page 8: ...licite est limit e une p riode d un an tel que stipul pour la garantie expresse L ENGAGEMENT DE BROAN NUTONE R PARER OU REMPLACER LE PRODUIT SON CHOIX CONSTITUE EXCLUSIVEMENT SA SEULE OBLIGATION DANS...

Reviews: